Removal of Halogenated Disinfection By-products Trichloroacetic Acid by Fe/Cu Catalytic Reduction in Drinking Water

Wenhai CHU,Naiyun GAO,Shijia ZHAO,Bingzhi DONG
DOI: https://doi.org/10.3969/j.issn.0253-374x.2009.10.015
2009-01-01
Abstract:Trichloroacetic acid (TCAA) which has relatively high concentration and carcinogenic risk, one of the most common disinfection by-products (DBPs) in drinking water, seriously endangers the physical health of mankind and eco-environment. Zero-valent iron (ZVI) reductive process is used in water treatment extensively for the removal of THMs by ZVI. However,little information is available on the removal of TCAA by low-cost Fe/Cu catalytic reduction technology. Some factors affecting the removal of TCAA by Fe/Cu catalytic reduction were studied including the impact of Fe/Cu mass ratio, Fe/Cu dosage, pH, organic matter concentration, and rotate speed on removing TCAA. The results show that Fe/Cu catalytic reduction can effectively remove TCAA from drinking water. The optimum Fe/Cu mass ratio, is 10:1, the dosage 30 g·L~(-1), and the pH between 4~8. The organic matter affects the removal of TCAA by Fe/Cu catalytic reduction in a negative way. 97. 39% of TCAA can be effectively removed by Fe/Cu catalytic reduction on the condition that the rotate speed of shaker is 200 r·min~(-1), the reaction time 160 min,Fe/Cu dosage 30 g·L~(-1) ,pH 6.82 and UV_(254) 0.117 cm~(-1). The influence of external diffusion on Fe/ Cu catalytic reductive reaction may be neglected. The degradation process of TCAA by Fe/Cu catalytic reduction is consistent with pseudo first order reaction.