Mechanism of dewatering-induced ground subsidence in deep subway station pit and calculation method

王建秀,吴林高,朱雁飞,唐益群,杨坪,娄荣祥
DOI: https://doi.org/10.3321/j.issn:1000-6915.2009.05.018
2009-01-01
Abstract:Monitoring data in Yishan Road station deep pit, subway No.9, Shanghai, China with multiple position extensometers indicate that the subsidence caused by dewatering of confined water has different rules: the accumulative multi-layered settlement is not equal to ground subsidence and some strata are not compressed but expansive. The mechanism is explained by combination of high-lower seepage characters, dewatering in deep confined aquifer-inversed rebound of overlaying strata, consolidation from deep-coordination of deformation and gradual boundary. The subsidence caused by dewatering in deep subway station pit is calculated by the accumulation method of each layer according to specification. A modified calculation method is established. Firstly, the single point deformation and compression in each layer are defined according to the law of inversed rebound, supposing that the inversed rebound and consolidation appear simultaneously but can be calculated separately; and the inversed rebound is measured by inversed rebound index. And the gradual consolidation is considered by layer division. When the inversed rebound value is greater than consolidation one, the strata will expand. The ground subsidence can be precisely predicted by the method when the inversed rebound index and drawdown are measured or calculated reasonably.
What problem does this paper attempt to address?