X-Pinch and Its Applications in X-Ray Radiograph

Xiaobing Zou,Xinxin Wang,Rui Liu,Tong Zhao,Naigong Zeng,Yongchao Zhao,Yanqiang Du
DOI: https://doi.org/10.1063/1.3192232
2009-01-01
Abstract:An X‐pinch device and the related diagnostics of x‐ray emission from X‐pinch were briefly described. The time‐resolved x‐ray measurements with photoconducting diodes show that the x‐ray pulse usually consists of two subnanosecond peaks with a time interval of about 0.5 ns. Being consistent with these two peaks of the x‐ray pulse, two point x‐ray sources of size ranging from 100 μm to 5 μm and depending on cut‐off x‐ray photon energy were usually observed on the pinhole pictures. The x‐pinch was used as x‐ray source for backlighting of the electrical explosion of single wire and the evolution of X‐pinch, and for phase‐contrast imaging of soft biological objects such as a small shrimp and a mosquito.