A Study on the Sound Field in a Vault with Two Open Ends

Hongjie Pu,Hequn Min,X. Qiu,Ji‐qing Wang
DOI: https://doi.org/10.3321/j.issn:0371-0025.2009.03.001
2018-01-01
Abstract:The sound field in a vault with two open ends is studied in this paper and its sound pressure distribution is compared with that in an enclosure and a long space. The accuracy of estimation on this kind of space by classic Sabine Formula, modified Sabine Formula and ray tracing method are compared through numerical and experimental results. Non-exponential decay is found in this open vault, and the reason and precondition of its occurrence are discussed. Ray tracing method has been used to conduct major numerical simulations in this article. Results of experiments have been compared with the numerical results to verify the conclusion. The steady sound pressure distribution in the vault with open ends is obviously different from that in enclosure and long space. The classic Sabine Formula cannot be used to calculate reverberation time in this open vault. As for the reason of the occurrence of non-exponential decay curve, it is because the coupling of sound energy between * Corresponding author. Tel.: +86 25 83592919; fax: +86 25 83592919 E-mail address: puhongjie@nju.edu.cn (H. Pu) small zones of different ‘live’ degrees within the space and it also depends on if requirements of double-sloped decay curve in coupled volumes theory can be fulfilled or not. If the distance between the observation spot and sound source is not big and both of them are not in the middle of the space, then double-sloped decay curve could be observed very obviously.
What problem does this paper attempt to address?