TMD Semi-Active Control with Shape Memory Alloy

SUN Wan-quan,LI Qing-bin
DOI: https://doi.org/10.3321/j.issn:0367-6234.2009.06.036
2009-01-01
Abstract:In view of the uncertain frequency of building structure vibration caused by random excitation or wind load,a SMA-TMD semi-active adaptive control system with reliable performance and simple structure is presented in this paper. The application of shape memory alloy in the variable stiffness TMD control equipment is investigated theoretically,and corresponding parameters are designed. Based on the study of dynamic characteristics of TMD system,the SMA-TMD adaptive control algorithm is designed by dint of short time Fourier transform. Simulation study indicates that the SMA-TMD system is effective and self-adaptive in identifying the time-frequency characteristic of the structure,and it is more robust and effective in reducing the vibration response compared with traditional TMD control.
What problem does this paper attempt to address?