Experimental Study for Noninvasive Monitoring of Hyperthermia Based on Features of Ultrasonic Echo

Lei SHENG,Chun-Lan YANG,Yan-Ping BAI,Yi Zeng,Shui-Cai WU
DOI: https://doi.org/10.3969/j.issn.0258-8021.2009.05.017
2009-01-01
Abstract:It is difficult to find a proper method to distinguish the necrotic tissue from the normal in the application of microwave hyperthermia. This paper discussed the change of ultrasonic echo during microwave hyperthermia in order to find proper parameters to realize noninvasive monitoring. Microwave heating method was used in gathering ultrasonic echo signals. Amplitude integral, energy and subtraction integral were computed. The results showed that the calculated parameters were relevant with tissue necrotic during hyperthermia. The echo amplitude, energy and non-uniformity increased after hyperthermia. Better result could be got by using ultrasonic backscatter integral and heterogeneity parameters to monitor hyperthermia.
What problem does this paper attempt to address?