Characteristics Analysis of Two Negative Artificially Triggered Lightning Discharges With Only Continuous Current

CHEN Shao-dong,ZHANG Yi-jun,YANG Shao-jie,DONG Wan-sheng,HUANG Zhi-hui,LU Wei-tao,ZHENG Dong
DOI: https://doi.org/10.3321/j.issn:0258-8013.2009.01.018
2009-01-01
Abstract:In this paper the characteristics of two lightning discharges (named F184626 and F185503) artificially triggered in Conghua, Guangzhou on Aug. 28 in 2006 were analyzed. Both of them are classical negative artificial lightning without return stroke besides continuous discharging and M component. Just before the triggering, the ground electric field is -6.1 kV/m and -8.2 kV/m respectively, and the triggered altitude of the two discharges are about 336 m and 244 m respectively. The results show that obvious double-polarity pulse occurs before the triggering of steady upper-ward positive leader, the average value of pulse interval is 18.12ms and 16.64ms respectively; obvious stepped leaders occur at the early stage of occurrence of stable streamer, and the average interval of stepped leader pulse is about 20 μs and 24 μs respectively; the total lasting time is about 250μs, and the width difference of pulses is basically 1 μs. The discharges on Aug. 28 in the summer of 2006 had much longer durations of continuous discharging than that in the north.
What problem does this paper attempt to address?