Fatigue life assessment of welds in bridge decks using long term monitored data

Guo Tong,Li Aiqun
DOI: https://doi.org/10.3321/j.issn:1000-131X.2009.06.011
2009-01-01
Abstract:Based on the structural health monitoring system of the Runyang Bridge, two years of strain monitoring on the welded rib-to-deck connections has been made. The electromagnetic interference is removed from the strain data by using the Butterworth filtering, and the strain cycles are extracted through the simplified rainflow counting algorithm. Thereafter fatigue reliability assessment is conducted by using the Palmgren-Miner rule and bilinear probabilistic S-N curves. According to the recorded ambient temperature, traffic volume and the fatigue equivalence of axle loadings, the influences of vehicle loadings and ambient temperature are analyzed. It can be found that the ambient temperature has an approximately linear effect on the fatigue damage of the welds in bridge decks. By comparison of the fatigue damage in weldeds between the Runyang Suspension Bridge (BSB) and the Runyang Cable-stayed Bridge (RCB), it is observed that the influence of temperature on the fatigue damage may widely exist in long-span cable-supported steel bridges. Based on the predicted traffic model and the fitted relationship of temperature, traffic loading and fatigue damage, results of the fatigue assessment are modified.
What problem does this paper attempt to address?