Influential factors of PTA simulated wastewater ultrsound-ozone treatment

Xiaoxiao Qiu,Yang Ding,Lihong Yin,Yuepu Pu,Wei Wu
2009-01-01
Abstract:Three approaches, ultrasound, ozone and ultrasound-ozone treatment, were applied to treat purified terephthalic acid (PTA) simulated wastewater. Their effects were compared, and the influences of ozone flow, ultrasound power and the initial concentration of wastewater on treatment effect were investigated. The results show that the ultrasound-ozone approach is the most efficient way for the treatment of PTA simulated wastewater. After 40 h treatment with ultrasound-ozone approach, the chemical oxygen demand (COD) of PTA simulated wastewater dropped from 3053.67 mg/L to 73.24 mg/L; the removal rate reaches 97.60%. Comparatively, the COD removal rate of ultrasound group and ozone group were 93.30% and 16.98%, respectively. Ozone flow, ultrasonic power and the initial concentration of wastewater are remarkable affecting factors of the degradation results. The increase of ultrasound power and ozone flow can improve the degradation efficiency of the PTA simulated wastewater.
What problem does this paper attempt to address?