Experimental Study and Design Recommendation on Concrete Cover Thickness of GFRP/steel Wire Composite Rebars

HAO Qingduo,WANG Yanlei,OU Jinping
DOI: https://doi.org/10.3321/j.issn:1000-6869.2009.03.011
2009-01-01
Abstract:The concrete cover thickness of GFRP/steel wire composite rebar in concrete structures is critical to the safety,serviceability and durability of the structures.Using the pull-out test,69 specimens were tested to measure the bond strength,the slip both at the loaded and free ends,and to calculate the load-slip relationship curves.The test parameters were the GFRP/steel wire composite rebar diameter,concrete compressive strength,and the concrete cover thickness.Based on the analysis of the test results,the critical value of slip at both loaded and free ends and the critical valRe of bond strength were obtained.and the design recommendation on concrete cover thickness of concrete structures reinforced with GFRP/steel wire composite rebars was suggested.The test results and design.recommendation can provide theoretical basis and references to the practical applications of the GFRP/steel wire composite rebars and to establishment of the related criterions.
What problem does this paper attempt to address?