Reliability-based multi-objective sensor location in water distribution systems

吴众华,张土乔,黄亚东,杨德军
DOI: https://doi.org/10.3785/j.issn.1008-973X.2009.06.016
2009-01-01
Abstract:A multi-objective optimal location model was put forward for sensor placement in water distribution systems under deliberate contamination events. Three design objectives were taken into account, including maximizing the detection likelihood, minimizing the expected detection time and maximizing the reliability of location plan. The contaminant concentration series at each node were simulated using EPANET2 when the water distribution system was suffered from contaminant injection, then the detection time matrix was generated based on Monte Carlo method. An improved non-dominated sorted genetic algorithm-II (NSGA-II) with integer code was proposed to solve this model. Pareto fronts were plotted among design objectives and sensitivity analysis was implemented. Both the number of sensors and the reliability criterion are significant to sensor location. The proposed location model is constructive for exploring trade-offs among multiple conflicting objectives for sensor location in water distribution systems.
What problem does this paper attempt to address?