Experimental Investigation of the Control System of a Diesel-Hybrid Powertrain

CAO Guijun,OUYANG Minggao
DOI: https://doi.org/10.3321/j.issn:1000-0054.2009.11.026
2009-01-01
Abstract:The energy management strategy and the auxiliary power unit (APU) control strategy determine the fuel economy and emissions of diesel-hybrid electric city buses. The performance of the energy management and APU control system was evaluated on a test bed for the hybrid electric power train that recorded engine fuel consumption, engine emissions and battery SOC during a typical city bus driving cycle in China. The results show that the APU feed forward and feedback control system can provide both constant speed and variable speed control. For a battery SOC of 40%, the fuzzy based energy management strategy and variable speed APU control reduces the fuel consumption by 20% compared with the original city bus whose fuel economy was 38 L/100 km. The constant speed APU control reduces the PM by 42% compared with the variable speed APU control but the fuel consumption increases by 5. 7% and the NO_x increases by 4%.
What problem does this paper attempt to address?