Flow Patterns and Optimization of Compartments for the Anaerobic Baffled Reactor
Ming Xu,Lili Ding,Ke Xu,Jinju Geng,Hongqiang Ren
DOI: https://doi.org/10.1080/19443994.2014.970580
IF: 1.1
2016-01-01
Desalination and Water Treatment
Abstract:The anaerobic baffled reactor (ABR) possesses many advantages such as high removal efficiency, outstanding working stability, and lower operating cost. In this essay, four reactors of equal effective volume (56.4 L) that were designed with three, four, five, and six compartments were adopted to investigate the flow patterns of the ABR through the tracer pulse stimulus-response technique and cold-model tests. The dead space decreases with the increase in the ABR compartments; specifically, the mean dead space induced by biomass and hydraulic behavior in 3-, 4-, 5-, and 6-compartment ABRs were 6.40, 5, 3.30, and 3%, respectively. In addition, the increase in ABR compartments also resulted in the decrease in back-mixing and 1/Pez values (from 0.118 to 0.060), which made the fluid in the reactor approach to the plug flow state. Analysis of the theoretical optimal number of ABR compartments shows that, the series number (N) of compartments shall be kept at 4N5 when the removal efficiency of the reaction system is 50% and 4N6 when the removal efficiency of the reaction system is 90%. Taking the operating performance and economic factors of the reactor into full consideration, the present study recommends that the series number (N) of ABR compartments shall be kept at 4 or 5.