Electrochemiluminescent behavior of N6-isopentenyl-adenine/Ru (bpy)3 2 + system on an electrically heated ionic liquid/carbon paste electrode

Zhenyu Lin,Xiaoping Chen,Hongqin Chen,Bin Qiu,Guonan Chen
DOI: https://doi.org/10.1016/j.elecom.2009.08.051
IF: 5.443
2009-01-01
Electrochemistry Communications
Abstract:A room temperature ionic liquid (IL), 1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF6) was used as a binder to prepare the electrically heated ionic liquid/carbon paste electrode (IL-HCPE). It has been found that N6-isopentenyl-adenine (2-ip) can enhance the electrochemiluminescent (ECL) intensity of Ru(bpy)32+. The electrode surface temperature (Te) has great effect on the ECL intensity of Ru(bpy)32+/2-ip system. The ECL intensities has a linear relationship with the concentration of 2-ip in the range of 1.0×10−7–1.2×10−6mol/L with a detection limit of 3.6×10−8mol/L (S/N=3) when Te was 58°C, while the linear range was of 5.0×10−7–1.0×10−6mol/L with a detection limit of 1.8×10−7mol/L under 27°C. It was also found that the reproducibility of this ECL system would be better at elevating temperature, the RSD were 7.2% and 1.5% for 8.0×10−7mol/L of 2-ip at 27 and 58°C, respectively. The possible mechanism of the Ru(bpy)32+/2-ip ECL system has been proposed also.
What problem does this paper attempt to address?