Abstract:The main disadvantage of Conventional Feuton (CF) treatment is the lack of Fe2+ due to the rapid oxidation of Fe2+ to Fe3+ To solve this problem, a Circulating Electro-Fenton reactor (CEF-FeRe) was employed to degrade dimethoate, during which H2O2was added to the electrolytic cell continuously by a peristaltic pump and Fe2+ could be regenerated to Fe3+ on the cathode. The operating conditions for this CEF-FeRe, such as pH value, electric current, Fenton reagent dosage, and the molar ratio of Fe2+ to H2O2 were optimized by individual factor experiments. The research results showed that the optimal conditions for dimethoate (200 mg·L-1) degradation are: pH=3.0,n(Fe2+)/n(H2O2)=0.1, electric current =0.5 A and Fentons reagent dosage at its theoretical dosage. Under these conditions, COD removal rates reached 81.67% within 120 min, while 99.4% of dimethoale was degraded within 25 min. The mechanism of the CEF-FeRe reaction was investigated by monitoring the changes of H2O2 and Fe concentration during the process. Kinetics results revealed that dimethoate oxidation follows the pseudo-first-order kinetic model at different pH values. Treatment of actual dimethoate wastewater by the CEF-FeRe showed that the removal rates of dimethoate and COD were about 91.16% and 68.53% , respectively, which indicated that the CEF-FeRe could be a cost-efficient method for dimethoate degradation.