Analysis of typical pollutants and its removal characteristics in the pretreatment of coking wastewater
Hengping WU,Chaohai WEI,Yuan REN,Jinhua WU,Ming LIU,Cong WEI
DOI: https://doi.org/10.16085/j.issn.1000-6613.2017-0310
2017-01-01
Abstract:Coking wastewater contains toxic refractory compounds in high loads,distributed between liquid and suspended solids.The pretreatment including gravity sedimentation,ammonia stripping/phenol extraction,coagulation/air floatation and ozonation was applied prior to biological treatment providing its effective performance.The removal of characteristic pollutants was studied in each pretreatment process.The results showed that 56.05% of suspended solids and 46.54% oil content were removed in 90min gravity sedimentation.Ammonia was stripped for 50min,and phenol was extracted using mixture of tributyl phosphate with 30% kerosene at pH=9,T=30℃,R=1 ∶ 4,n=3.Ammonia and phenol were recovered for 69.85% and 76.02%,respectively.At the FeSO4 dosage of 1500mg/L and initial pH=9,coagulation/air floatation removed sulfide,cyanide and ammonia for 89.93%,60.68% and 2.95%,respectively.At the concentration of gaseous ozone 14mg/L±1mg/L and initial pH =10,sulfide,cyanide and ammonia were degraded as a result of 80min ozonation for 94.92%,91.05% and 47.26%,respectively.The results obtained in the study may serve the optimization of the pretreatment process,targeting the purification performance and the economic efficiency with the separation of phases,the recovery of chemical products and the transformation of toxic pollutants.