Experimental investigation of convection heat transfer of CO2 at supercritical pressures in vertical circular tube
Zhi-Hui Li,Pei-Xue Jiang,Chen-Ru Zhao,YuSong Lin
2010-01-01
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Abstract:The convection heat transfer characteristics of supercritical CO 2 in a vertical circular tube of 2 mm inner diameter were investigated experimentally for pressures ranging from 78 to 95 bar, inlet temperatures from 25 to 40 °C, and inlet Reynolds numbers from 3800 to 20,000. The effects of the heat flux, thermo-physical properties, buoyancy and thermal acceleration on the convection heat transfer were analyzed. The experimental results show that for high inlet Reynolds numbers (e.g. Re = 9000) and high heat fluxes, a significant local deterioration and recovery of the heat transfer was found for upward flows but not for downward flows. Comparison of the experimental data for inlet Reynolds numbers from 3800 to 20,000 with some well-known empirical correlations showed large differences especially when the heat transfer deteriorates and then recovers when the effect of buoyancy is significant. The experimental data was used to develop modified local turbulent Nusselt number correlations for supercritical CO 2 flowing in vertical small circular tubes. Keywords Supercritical pressures Buoyancy Thermal acceleration Empirical correlations Nomenclature c p specific heat at constant pressure [J/(kg K)] c ¯ p average specific heat [J/(kg K)] d tube inner diameter [m] D tube outer diameter [m] A surface area [m 2 ] G mass flow rate [kg/s] I current [A] l tube length [m] p pressure [N/m 2 ] q v internal heat source strength (4 I 2 R /( π ( D 2 − d 2 ) L )) [W/m 3 ] q w heat flux on the inner tube surface [W/m 2 ] Q loss heat loss from the test section [W] R electrical resistance [Ω] T temperature [°C] or [K] T pc pseudo-critical temperature [°C] or [K] x axial coordinate [m] h f ,0 inlet specific enthalpy [J/kg] h f , b ( x ) local bulk fluid enthalpy [J/kg] h w specific enthalpy at the wall temperature [J/kg] h b specific enthalpy at the bulk temperature [J/kg] h x local heat transfer coefficient [W/(m 2 °C)] Nu Nusselt number Pr Prandtl number Re Reynolds number Gr Grashof number ( Gr = gβd 3 ( T w − T f )/ ν 2 ) Gr * Grashof number ( Gr ∗ = g β d 4 q w / λ ν 2 ) Greek symbols λ thermal conductivity [W/(m K)] ρ density [kg/m 3 ] μ dynamic viscosity [kg/(m s)] Subscripts b bulk f fluid i inner surface in inlet section o outer surface out outlet section w wall x local values 0 tube inlet 1 Introduction Recently, the development of the supercritical pressure water-cooled reactor (SCWR) and other industrial applications such as trans-critical CO 2 air-conditioning and heat pump systems have led to a new interest in the heat transfer to fluids at supercritical pressures. There were many papers published on forced and mixed convection heat transfer in supercritical fluids such as water, carbon dioxide, nitrogen, hydrogen, and helium in large tubes during the late nineteen fifties and throughout the sixties [1–5] . The findings provided a comprehensive understanding of some special features of the heat transfer in large tubes. In contrast, there is little data for narrow geometries (∼2.5 to 3 mm), which are typical of the equivalent diameters of the fuel element sub-channels in an SCWR. The operating conditions for the SCWR are very complex, with little knowledge on the heat transfer mechanisms in narrow geometries, especially the effect of variable physical properties, buoyancy effects, and thermal acceleration on the heat transfer. Song et al. [6] investigated the heat transfer of supercritical pressure CO 2 in vertical tubes having 4.4 mm and 9.0 mm inner diameters. The results showed that a similarity of heat transfer behavior was maintained both in the normal heat transfer mode and deteriorated heat transfer mode with the same length to diameter ratio and the wall heat flux to mass flux ratio. Jiang et al. [7,8] experimentally and numerically investigated the local convection heat transfer of CO 2 at supercritical pressures in vertical mini-tubes having 0.27 mm and 2 mm inner diameters at relatively low Reynolds for upward and downward flows. The experiments investigated the effects of heat flux, mass flow rate, inlet fluid temperature, buoyancy and flow acceleration on the convection heat transfer. However, the length to diameter ratio of the 2 mm inner diameter tube was relatively small ( l / d = 19.5), so the axial conduction effect is significant. Many earlier supercritical heat transfer correlations [9] have been shown to be in good agreement with experimental data when buoyancy is not significant but these correlations differ significantly from the experimental data when buoyancy effects are significant. Protopopov [10] and McEligot and Jackson [11] utilized buoyancy parameters in their correlations, but their correlations were based on data for large tubes so their results need to be verified for small channels. Jong et al. [12] developed a correlation to predict the forced heat transfer and mixed heat transfer over a wide range of operating conditions taking into account the imposed conditions such as mass flow rate and heat flux based on data for circular, triangular, and square cross-sections. Hyungrae et al. [13] developed new correlations to predict the normal heat transfer rate and the reduced heat transfer rate to supercritical pressure CO 2 based on experimental data for tubes having inner diameters of 4.4 mm and 9.0 mm and a concentric annular passage (8 mm × φ 10 mm × L 1800 mm). Further studies of the heat transfer mechanism in supercritical pressure fluids are needed to improve predictions of the heat transfer coefficient in the narrow geometries, especially for the SCWR design. This paper describes experimental investigations of the local convection heat transfer of supercritical pressure CO 2 flowing in a vertical 2 mm inner diameter long mini-tube for upward and downward flows over a wide range of parameters. The local external wall temperatures along the tube were measured directly in the experiments and the corresponding local Nusselt numbers along the tube as well as the dimensionless parameter Bo * for evaluating the buoyancy effect and Kν for evaluating the thermal acceleration effect were presented. The tests investigated the effects of heat flux, flow direction, buoyancy and thermal acceleration on the convection heat transfer. The experimental data for inlet Reynolds numbers from 3800 to 20,000 are then compared with existing correlations for upward and downward flows. Modified local turbulent Nusselt number correlations are presented in this paper. 2 Experimental facility 2.1 Experimental system and test section The experimental system is schematically shown in Fig. 1 which was presented in Jiang et al. [8] . The working fluid, CO 2 with a purity of 99.995%, was fed into the test loop from a compressed CO 2 container. The working fluid was cooled by a cooling bath before being pressurized and driven by a supercritical CO 2 pump (Thar P-50). Then the fluid flowed through a pre-heater in which it was heated to the desired inlet temperature for each test and then into a vertical test section and a cooler and finally returned to the pump. The system pressure was regulated by a decompression valve. The test section was a vertical stainless steel 1Cr18Ni9Ti long tube with inside and outside diameters of 2.018 mm and 3.137 mm. The heated test section was 290 mm long with heating by an AC current. The test section was connected with the test loop by flanges and high-pressure fittings. The test section was insulated thermally and electrically from the test loop by a layer of PTFE placed between the flanges and between the screws and the flanges. CO 2 flowed into the test section from either the bottom for upward flow or from the top for downward flow. The heated length to inner diameter ratio was 145 which is much larger than in the previous work [8] . The tube also included 105 mm long inlet and outlet sections to guarantee fully developed flow. The measurements using a Talysurf 5P showed that the average inner surface roughness of the mini-tube was 0.14 μm to assure the teat section is smooth tube. The whole test section was wrapped by a layer of thick asbestos to reduce heat losses. The orientation of flow includes upward flow and downward flow. 2.2 Measurements The local outer wall temperatures were measured by 33 copper-constantan type thermocouples with diameters of 0.2 mm spot-welded onto the outer surface along the tube. The first two and last two thermocouples were 5 mm apart, with the rest of the thermocouples 9 mm apart. The inlet and outlet bulk temperatures were measured by two accurate RTDs inserted inside the tube through a tee-junction at the inlet and outlet of the heated section. Mixers were installed before the temperature measurement positions to ensure complete mixing before the bulk temperature measurement. The inlet pressure was measured by a pressure transducer (Model EJA430A) with a full range of 14 MPa. The test section pressure drop was measured by a differential pressure transducer (Model EJA110A) with a full range of 10 kPa. The mass flow rate was measured by a Coriolis-type mass flow meter (Model MASS2100-DI1.5) with the full range of 4 kg/h. The electric power inputs to the test section were calculated from the measured current, voltage and electrical resistance. The measured data including the pressure, differential pressure, temperature and mass flow rate were monitored and recorded by a data acquisition system (HP 34970A). The experiments covered a wide range of parameters as listed in Table 1 . 3 Data analysis method and experimental uncertainty The local heat transfer coefficient, h x , and the local Nusselt number, Nu x at each axial location were calculated from the following equation: (1) h x = q w T w , i ( x ) - T f ( x ) , Nu x = h x d λ The heat transport in the tube wall was assumed to be one-dimensional steady thermal conduction with a local uniform volumetric heat source in the tube. The boundary conditions assumed an insulated outer surface with the measured local temperatures for the outer tube surface, T wo ( x ). The local temperatures for the inner tube surface, T wi ( x ), were then calculated with the following equation (Jiang et al. [8] ): (2) T w , i ( x ) = T w , o ( x ) + q v 16 λ ( D 2 - d 2 ) + q v 8 λ D 2 ln d D The heat flux on the inner surface, q w , was calculated as: (3) q w = I 2 R - Q loss A i Q loss represents the overall heat losses as a function of temperature difference between the wall temperature and the surroundings. Q loss was obtained experimentally by changing the heating power without fluid flow in the test system. The local bulk fluid temperature, T f ( x ), was calculated from the local bulk fluid enthalpy, h f ( x ), as: (4) h f ( x ) = h f , 0 + q w π dx G The dimensionless independent parameters Re , Gr and Gr * were calculated from the measured quantities using: (5) Re = ρ ud μ = 4 G π d μ , Gr = g β d 3 ( T w - T f ) ν 2 , Gr ∗ = g β d 4 q w λ ν 2 The accuracies were within ±0.25 °C for the copper-constantan type thermocouples and ±0.1 °C for the RTDs in the temperature range of 0–150 °C. The accuracy of the pressure gage transducer was 0.075% of a full range of 14 MPa. The accuracy of the differential pressure transducer was 0.075% over a range of −5 to 5 kPa. According to the instructions, the accuracy of the Coriolis-type mass flow meter (Model MASS2100-DI1.5) was 0.1% of the actual mass flow rate with 95% confidence (probability) for flows within 5–100% of the sensor’s maximum flow rate. The flow rate during the measurements was about 1.6–3.68 kg/h. Therefore, the relative uncertainty of the mass flow rate was 0.1%. A detailed analysis of the uncertainty showed that the maximum uncertainty of the heating rate into the test section was ±4.0%, the uncertainty of the tube inner surface temperatures was ±0.25 °C and the uncertainty of the local bulk fluid temperature was ±0.24 °C. The root-mean-square uncertainty of the Nusselt number was then estimated to be ±7.9%. The uncertainties in the inlet pressures were estimated to be ±0.13%. 4 Experimental results and discussion 4.1 Parameters for buoyancy effect on the convection heat transfer The buoyancy parameter, K , introduced by Protopopov [10] can be used to estimate the influences of buoyancy on the heat transfer. The buoyancy number, K , was defined as: (6) K = ( 1 - ρ w / ρ b ) · Gr / Re 2 According to Protopopov [10] , for upward flow, when K < 0.01, the buoyancy does not significantly affect the heat transfer, when 0.01 < K < 0.4, the buoyancy will significantly reduce the heat transfer; however, when K > 0.4, the buoyancy will enhance the heat transfer. For downward flow, the buoyancy will always enhance the heat transfer. Another buoyancy parameter, Bo * , introduced by Jackson et al. [4] can also be used to estimate the influences of buoyancy on the heat transfer. The buoyancy number, Bo * , was defined as: (7) Bo ∗ = Gr ∗ / ( Re 3.425 Pr 0.8 ) According to McEligot and Jackson [11] , the buoyancy is negligible for Bo * < 6 × 10 −7 for upward and downward flows. For upward flow with 6 × 10 −7 < Bo * < 1.2 × 10 −6 , the buoyancy will reduce the heat transfer while for 1.2 × 10 −6 < Bo * < 8.0 × 10 −6 , the heat transfer reduction will be gradually weakened as the Bo * increases but the buoyancy will still negatively affect the heat transfer. For Bo * > 8.0 × 10 −6 the buoyancy will enhance the heat transfer. For downward flow, the buoyancy will always enhance the heat transfer for Bo * > 6 × 10 −7 4.2 Parameter for thermal acceleration effect on the convection heat transfer The thermal acceleration parameter, Kν , introduced by McEligot et al. [14] to estimate the influence of the thermal acceleration on the heat transfer: (8) K ν = 4 q w d β Re 2 μ c p McEligot et al. [14] suggested that for turbulent flows, when Kν < 3 × 10 −6 the fluid flow remains turbulent, but when Kν ⩾ 3 × 10 −6 the turbulence may be reduced which results in the deteriorated heat transfer. 4.3 Convection heat transfer at relatively high Reynolds numbers ( Re in = 9000) 4.3.1 Convection heat transfer for low heat fluxes Fig. 2 a and b shows the local wall temperatures (solid symbols) and local bulk fluid temperatures (hollow symbols) along the tube for upward and downward flows for low heat fluxes ( q w = 6498 W/m 2 , 7926 W/m 2 , 13,626 W/m 2 in Fig. 2 a and q w = 6494 W/m 2 , 7930 W/m 2 , 13,399 W/m 2 in Fig. 2 b) at an inlet pressure of 8.80 MPa, inlet temperature of 25.0 °C, and inlet Reynolds number of 9000. The inlet fluid temperature is less than the pseudo-critical temperature ( T pc = 39.1 °C for p = 8.80 MPa). As can be seen from these figures, the local wall temperature increases continually along the tube for both upward and downward flows without abnormal temperature variations with the local wall temperatures and fluid temperatures both lower than the pseudo-critical temperature. Fig. 3 a and b shows the local Bo * distributions along the tube for upward and downward flows with the same conditions as in Fig. 2 a and b. The local Bo * are less than 6 × 10 −7 for the lower heat fluxes ( q w = 6498 W/m 2 and 7926 W/m 2 in Fig. 2 a and q w = 6494 W/m 2 and 7930 W/m 2 in Fig. 2 b) , Bo * approaches but is still less than 6 × 10 −7 for the higher heat fluxes ( q w = 13,626 W/m 2 in Fig. 2 a and q w = 13,399 W/m 2 in Fig. 2 b). According to McEligot and Jackson [11] the influence of buoyancy on the heat transfer is still negligible. However, this is not true as will be analyzed later when discussing Fig. 5 . Fig. 4 a and b shows the local Kν distributions along the tube for upward and downward flows for the same conditions as in Fig. 2 a and b. The local Kν are much less than 3 × 10 −6 for all the heat fluxes, which means that the influence of thermal acceleration on the heat transfer is negligible. Fig. 5 a and b shows the local Nusselt number distributions for upward and downward flows for the same conditions as in Fig. 2 a and b. The local Nusselt number first decreases along the flow direction in the entrance region as the boundary layer develops along the tube and then increases further down the tube. Since the wall and fluid temperatures along the tube are lower than the pseudo-critical temperature, Fig. 2 , as the fluid bulk temperature increases along the tube, the viscosity and thermal conductivity decrease while the specific heat ( c p ) significantly increases, as shown in Fig. 6 . The decreased thermal conductivity reduces the heat transfer, but the decreased viscosity makes the viscous sub-layer thinner which enhances the heat transfer. The sharp increase of the specific heat significantly enhances the heat transfer due to the increased convection transport capacity. Therefore, the local Nusselt number decreases along the tube only in a short entrance region, and then increases further down the tube. As can be seen from Fig. 5 , the local Nusselt number increases with increasing heat flux due to the influence of the thermo-physical properties with the buoyancy having little effect with q w = 6498 W/m 2 and q w = 7926 W/m 2 for upward flow and q w = 6494 W/m 2 and q w = 7930 W/m 2 for downward flow. However, at the higher heat flux of q w = 13,626 W/m 2 the heat transfer was impaired relative to that with the lower heat flux for upward flow, when the heat transfer was increased at the heat flux of q w = 13,399 W/m 2 , relative to that with the lower heat flux for downward flow. These results illustrate that the influence of buoyancy on the heat transfer occurs earlier than Bo * = 6 × 10 −7 given by McEligot and Jackson [11] . 4.3.2 Convection heat transfer for high heat fluxes Fig. 7 a and b shows the local wall temperatures (solid symbols) and local bulk fluid temperatures (hollow symbols) along the tube for four higher heat fluxes ( q w = 26,784 W/m 2 , 31,882 W/m 2 , 39,389 W/m 2 , 51,955 W/m 2 in Fig. 7 a and q w = 26,703 W/m 2 , 31,786 W/m 2 , 38,706 W/m 2 , 50,378 W/m 2 in Fig. 7 b) at an inlet pressure of 8.80 MPa, inlet temperature of 25.0 °C, and inlet Reynolds number of 9000 for upward and downward flows. For these conditions, the local wall temperature is higher than T pc and the local bulk fluid temperature approaches the pseudo-critical temperature along the tube. For upward flows, the local wall temperature first increases, then decreases, then increases again along the tube, and finally decreases in the outlet region due to the longitudinal conduction. For downward flows, the local wall temperature increases continuously along the tube without abnormal temperature variations, except for the temperature decreasing slightly at the outlet due to the end effect. Fig. 8 a and b shows the local Bo * distributions along the tube for upward and downward flows for the same conditions as in Fig. 7 a and b. These local Bo * are greater than 6 × 10 −7 and even larger than 1.2 × 10 −6 , which means that the buoyancy has a significant influence on the heat transfer. Fig. 9 a and b shows the local Kν distributions along the tube for upward and downward flows for the same conditions as in Fig. 7 a and b. The local Kν are less than 3 × 10 −6 for both upward and downward flows which means that the thermal acceleration has little influence on the heat transfer. Fig. 10 a and b shows the local Nusselt number distributions for upward and downward flows for the same conditions as in Fig. 7 a and b. For the upward flows, the local Nusselt number first decreases to a local minimum along the tube, then increases to a maximum, then decreases again, and then finally increases downstream in the tube illustrating the significant local deterioration and recovery of the heat transfer. The turbulent diffusivity is reduced for upward flow when the low-density wall layer which results in strong buoyancy becomes thick enough to reduce the shear stress in the region where energy is typically fed into the turbulence; thus, significantly reducing the heat transfer. Therefore, The Nusselt number decreases to a local minimum as the wall temperature increases to a maximum as shown in Figs. 10 and 7 a. Further along the tube, the increasing wall temperature further increases the density difference between the near wall region and the bulk. This density difference becomes more significant which causes upward acceleration of the fluid in the boundary layer and enhances the turbulence production and, hence, the heat transfer. As a result, The Nusselt number increases to a local maximum as the wall temperature decreases along the tube to a minimum as shown in Figs. 10 and 7 a. As the wall temperature further increases along the latter part of the tube, the fluid temperature near the wall region is greater than the pseudo-critical temperature. The variation of the thermo-physical properties, especially the specific heat, then strongly reduces the heat transfer. As a result, The Nusselt number decreases again as the wall temperature increases along the tube. In the outlet region, The Nusselt number increases as the wall temperatures decrease somewhat due to the effect of the axial thermal conduction. For downward flows, the local Nusselt number decreases along the flow direction in the entrance region as the boundary layer develops and then increases to a maximum due to the increase of the specific heat and the decrease of the viscosity as the bulk temperature approaches T pc and the turbulence is enhanced by the buoyancy. Further downstream, the near-wall layer fluid temperature increases and passes through T pc as the wall temperature increases, the specific heat decreases and the viscosity increases so that the local Nusselt number decreases as a result. At higher heat fluxes, the maximum local Nusselt number is closer to the inlet as shown in Fig. 10 b. Deterioration of the heat transfer was not observed for downward flows. The Nusselt number increases along the tube for downward flow mainly due to the variations of the thermo-physical properties and the strong buoyancy which increase the turbulence energy and, hence, the heat transfer. The decrease of the local Nusselt number with increasing heat flux was due to the decreased specific heat, density, and thermal conductivity when the wall temperature was much larger than T pc as shown in Figs. 6 and 7 . 5 Comparison with existing empirical correlations 5.1 Experimental results Fig. 11 shows the ratio of the local Nusselt number for mixed convection to that for forced convection for pressures ranging from 78 to 95 bar, inlet temperatures from to 25 to 40 °C, and inlet Reynolds numbers from 3800 to 2 × 10 4 plotted against local values of the buoyancy parameter. In determining Nu / Nu f and Bo * , the fluid properties were evaluated at the bulk temperature with Nu f equal to Nu b in Eq. (12) multiplied by ε l from Eq. (9) . The results show the contrasting behavior for upward and downward flows. For downward flow, the heat transfer is enhanced by the buoyancy influence as has been found in larger circular tubes. For upward flow, the heat transfer decreases with increasing buoyancy for 2 × 10 −7 < Bo * < 6 × 10 −7 followed by recovery of the heat transfer for 6 × 10 −7 < Bo * < 2 × 10 −5 and improved heat transfer for Bo * > 2 × 10 −5 which is similar to that found in larger circular tubes, but with different ranges of Bo * . 5.2 Heat transfer without buoyancy effects Krasnoshchekov and Protopopov [2] and Grigoriev et al. [15] developed empirical correlations for the local Nusselt numbers for turbulent and transition convection heat transfer in vertical tubes: (9) Nu ( x / d ) = Nu 0 ε l ( x / d ) ε ϕ ( x / d ) where ε l = 1 + 2.35 Pr f - 0.4 Re f - 0.15 ( x / d ) - 0.6 exp ( - 0.39 Re f - 0.1 · x / d ) ε φ = ( ρ w / ρ b ) m · ( c ¯ p / c pb ) n upward flow : m = 0.4 ; downward flow : m = 0.3 c ¯ p = ∫ T b T w c p dT / ( T w - T b ) = ( h w - h b ) / ( T w - T b ) when c ¯ p / c pb > 1 , n = 0.7 when c ¯ p / c pb < 1 ′ , n = 0.4 for T w < T pc or T b ⩾ 1.2 T pc n 1 = 0.22 + 0.18 ( T w / T pc ) for T b < T pc and 1 < T w T pc < 2.5 n 1 - ( 5 n 1 - 2 ) [ T b / T pc - 1 ] for 1 < T b T pc < 1.2 where Nu 0 is calculated using the formulas proposed by Petukhov et al. [16] and Gnielinski [17] : (10) Nu 0 = ( ζ / 8 ) ( Re - 1000 ) Pr 1 + 12.7 ζ / 8 ( Pr 2 / 3 - 1 ) ( for 2300 ⩽ Re ⩽ 0 4 ; 0.5 ⩽ Pr ⩽ 200 ) (11) Nu 0 = ( ζ / 8 ) Re · Pr 1 + 900 / Re + 12.7 ζ / 8 ( Pr 2 / 3 - 1 ) ( for 10 4 ⩽ Re ⩽ 5 × 10 6 , 0.5 ⩽ Pr ⩽ 5 × 10 5 ) ζ = ( 1.82 log Re - 1.64 ) - 2 The Jackson correlation [18] for flow without buoyancy is given by: (12) Nu b = 0.0183 Re b 0.82 Pr b 0.5 ( c ¯ p / c pb ) n ( ρ w / ρ b ) 0.3 where n = 0.4 T b < T w < T pc , 1.2 T pc < T b < T w 0.4 + 0.2 ( T w / T pc - 1 ) T b < T pc < T w 0.4 + 0.2 ( T w / T pc - 1 ) [ 1 - 5 ( T b / T pc - 1 ) ] T pc < T b < 1.2 T pc , T b < T w Fig. 12 a and b compares Eqs. (9)–(11) with the current experimental data for K less than 0.01 for upward and downward flows. Here, the ordinate, Nu p , is the value predicted by the correlations and the abscissa, Nu e , is the experimental value. The Krasnoshchekov and Protopopov correlation, Eq. (9) , captures 95% of the data with an accuracy of ±15%. Fig. 13 a and b compares Eq. (12) with the current experimental data for B o * less than 6 × 10 −7 for upward and downward flows. The Jackson correlation captures 95% of the data with an accuracy of ±20%. The differences in Fig. 13 are greater than with Eqs. (9)–(11) in Fig. 12 , one reason is that the effect of the thermal entry region is not considered in Eq. (12) . Eqs. (9) and (12) can accurately predict the heat transfer coefficients without buoyancy as shown by the good agreement with the present experimental data. 5.3 Heat transfer with buoyancy The correlation proposed by Protopopov [10] for flow with buoyancy is given by: (13) Nu b ( 2 ) = Nu b 1 ϕ ( 2 ) ( K ) ( 0.01 < K < 0.4 ) (14) Nu b ( 3 ) = Nu b 1 ϕ ( 3 ) ( K ) , ( K > 0.4 ) where Nu b 1 is obtained from Eqs. (9)–(11) . φ (2) ( K ) and φ (3) ( K ) were given by Protopopov [10] . The semi-empirical model proposed by McEligot and Jackson [11] is given by: (15) Nu Nu f = 1 ± 8 × 10 4 Gr ∗ Re 3.425 Pr 0.8 Nu Nu f - 2 0.46 where “+” is for downward flow, “−” is for upward flow and Nu f is obtained from Eq. (12) . Fig. 14 a and b compares Eqs. (13), (14) with the experimental data for K greater than 0.01 for upward and downward flows. The Protopopov correlation captures 95% of the data with an accuracy of ±35%. Large differences occur between the predicted and experimental values, especially where the heat transfer deteriorates and then recovers for upward flow where the bulk fluid temperature and wall temperature are near the pseudo-critical temperature. Fig. 15 a and b compares Eq. (15) with the experimental data for Bo * greater than 6 × 10 −7 for upward and downward flows. The Jackson correlation captures 95% of the data with an accuracy of ±30% for upward flow and ±25% for downward flow. 5.4 Modified local Nusselt correlations for turbulent heat transfer The current experimental data was analyzed to develop new local Nusselt number correlations for turbulent heat transfer with buoyancy effects for carbon dioxide flow at supercritical pressures flowing in vertical small circular tubes: For downward flow: (16) Nu Nu f = 1 + ( Bo ∗ ) 0.1 c ¯ p c pb - 0.3 ρ w ρ b 0.5 Nu Nu f - 2 0.46 For upward flow: (17) Nu Nu f = 1 - ( Bo ∗ ) 0.1 c ¯ p c pb - 0.009 ρ w ρ b 0.35 Nu Nu f - 2 0.46 where Nu f is equal to Nu b from Eq. (12) multiplied by ɛ l from Eq. (9) . Fig. 16 a and b compares Eqs. (16) and (17) with the experimental data for upward and downward flows. The correlations capture 95% of the data with an accuracy of ±20%, with relatively accurate predictions of the deterioration and recovery of the convection heat transfer for upward flow and the heat transfer enhancement for downward flow. 6 Conclusions (1) For a higher inlet Reynolds number, Re in = 9000, and lower heat fluxes, the local wall temperatures increase along the tube for upward and downward flows. However, for high heat fluxes, the local wall temperatures vary in a complex, nonlinear fashion with deterioration and recovery of the heat transfer observed in upward flows but not in downward flows. (2) For upward flow, the heat transfer decreases with increasing buoyancy for 2 × 10 −7 < Bo * < 6 × 10 −7 followed by recovery of the heat transfer for 6 × 10 −7 < Bo * < 2 × 10 −5 and improved heat transfer for Bo * > 2 × 10 −5 . (3) The Krasnoshchekov correlation and the Jackson correlation are applicable for turbulent heat transfer without buoyancy effects and are in good agreement with the current experimental data. (4) The current experimental data was used to develop local Nusselt number correlations to predict the heat transfer with buoyancy effects for upward and downward turbulent flows of carbon dioxide at supercritical pressures in vertical circular tubes. The correlations more accurately represent the data and accurately predict the complex Nusselt number variations resulting from complex thermo-physical property variation and buoyancy effects. Acknowledgements This project was supported the Key Project Fund from the National Natural Science Foundation of China (No. 50736003) and the National High Technology Research and Development Program of China (863 Program) (No. 2006AA05Z416). We thank Professor J.D. Jackson in the School of Mechanical, Aerospace and Civil Engineering, the University of Manchester, UK for many suggestions for this paper. We also thank Prof. David Christopher for editing the English. References [1] M.E. Shitsman Impairment of the heat transmission at supercritical pressures High Temperature 1 1963 237 244 [2] E.A. Krasnoshchekov V.S. Protopopov Experimental study of heat exchange in carbon dioxide in the supercritical range at high temperature drops Teplofizika Vysokikh Temperature 4 3 1966 389 398 (in Russian) [3] B.S. Petukhov Heat Transfer and Friction in Turbulent Pipe Flow with Variable Physical Properties, Advances in Heat Transfer vol. 6 1970 Academic Press New York [4] J.D. Jackson M.A. Cotton B.P. Axcell Studies of mixed convection in vertical tubes International Journal of Heat and Fluid Flow 10 1 1989 2 15 [5] V.A. Kurganov A.G. Kaptilnyi Flow structure and turbulent transport of a supercritical pressure fluid in a vertical heated tube under the conditions of mixed convection International Journal of Heat and Mass Transfer 36 13 1993 3383 3392 [6] J.H. Song H.Y. Kim H. Kim Y.Y. Bae Heat transfer characteristics of a supercritical fluid flow in a vertical pipe The Journal of Supercritical Fluids 44 2008 164 171 [7] P.X. Jiang Y. Zhang C.R. Zhao R.F. Shi Convection heat transfer of CO 2 at supercritical pressures in a vertical mini tube ar relatively low Reynolds numbers Experimental Thermal and Fluid Science 32 2008 1628 1637 [8] P.X. Jiang Y. Zhang Y.J. Xu R.F. Shi Experimental and numerical investigation of convection heat transfer of CO 2 at supercritical pressures in a vertical tube at low Reynolds numbers International Journal of Thermal Sciences 47 2008 998 1011 [9] I.L. Pioro H.F. Khartabil R.B. Duffey Heat transfer to supercritical fluids flowing in channels – empirical correlations (survey) Nuclear Engineering and Design 230 1–3 2004 69 91 [10] V.S. Protopopov Generalized correlations for local heat transfer coefficient for turbulent flow of water and carbon dioxide at supercritical pressure in uniformly heated tubes Teplofizika Vysokikh Temperature 15 4 1977 815 821 (in Russian) [11] D.M. McEligot J.D. Jackson “Deterioration” criteria for convective heat transfer in gas flow through non-circular ducts Nuclear Engineering and Design 232 2004 327 333 [12] K.K. Jong K.J. Hong S.L. Joon Wall temperature measurement and heat transfer correlation of turbulent supercritical carbon dioxide flow in vertical circular/non-circular tubes Nuclear Engineering and Design 237 2007 1795 1802 [13] K. Hyungrae Y.K. Hwan H.S. Jin Y.B. Yoon Heat transfer to supercritical pressure carbon dioxide flowing upward through tubes and a narrow annulus passage Progress in Nuclear Engineering 50 2008 518 525 [14] D.M. McEligot C.W. Coon H.C. Perkins Relaminarization in tubes International Journal of Heat and Mass Transfer 13 1970 431 433 [15] V.S. Grigoriev A.F. Polyakov S.V. Rosnovsky Heat transfer of fluids at supercritical pressures with variable heat flux along length in tubes Teplofizika Vysokikh Temperature 15 6 1977 1241 1247 (in Russian) [16] B.S. Petukhov L.G. Genin S.A. Kovalev H eat Transfer in Nuclear Power Equipment 1986 Energoatomizdat Press Moscow (in Russian) [17] V. Gnielinski New equations for heat and mass transfer in turbulent pipe and channel flows International Chemical Engineering 16 1976 359 368 [18] J.D. Jackson, Consideration of the heat transfer properties of supercritical pressure water in connection with the cooling of advanced nuclear reactors, in: Proceedings of the 13th Pacific Basin Nuclear Conference, Shenzhen, China, October 21–25, 2002.
What problem does this paper attempt to address?
-
Convection Heat Transfer of Co2 at Supercritical Pressures in A Vertical Mini Tube
Pei-Xue Jiang,Zhi-Hui Li,Chen-Ru Zhao
DOI: https://doi.org/10.1115/mnhmt2009-18343
2010-01-01
Abstract:This paper presents the experimental and numerical investigation results of the convection heat transfer of CO2 at supercritical pressures in a 0.0992 mm diameter vertical tube at various inlet Reynolds numbers, heat fluxes and flow directions. The effects of buoyancy and flow acceleration resulted from the dramatic properties variation were investigated. Results showed that the local wall temperature varied non-linearly for both upward and downward flow when the heat flux was high. The difference of the local wall temperature between upward flow and downward flow was very small when other test conditions were held the same, which indicates that for supercritical CO2 flowing in a mini tube as employed in this study, the buoyancy effect on the convection heat transfer was quite insignificant, and the flow acceleration induced by the axial density variation with temperature was the main factor that lead to the abnormal local wall temperature distribution at high heat fluxes. The predicted values using the LB low Reynolds number turbulence model correspond well with the measured data. Velocity profiles and turbulence kinetic energy near the wall varying along the tube generated by the numerical simulations were presented to develop a better understanding.
-
Convection heat transfer of supercritical pressure carbon dioxide in a vertical micro tube from transition to turbulent flow regime
Peixue Jiang,Bo Liu,ChenRu Zhao,Feng Luo
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2012.08.038
IF: 5.2
2013-01-01
International Journal of Heat and Mass Transfer
Abstract:This paper presents experimental investigations of the convection heat transfer of carbon dioxide at supercritical pressures in a vertical tube with inner diameter of 99.2μm for various Reynolds numbers, heat fluxes and flow directions. The effects of buoyancy and flow acceleration due to heating and pressure drop are evaluated and analysed. The results show that the effects of flow acceleration are significant and the local wall temperature varies non-linearly for both upward and downward flows at the pressures in the vicinity of critical point and low inlet Reynolds numbers when the heat fluxes are relatively high. The buoyancy effect on the heat transfer is negligible in micron scale tubes at inlet Reynolds (from 2600 to 6700) and various heat fluxes (from 85kW/m2 to 748kW/m2). The flow acceleration due to heating and pressure drop can strongly influence the turbulence and reduce the heat transfer for high heat fluxes and low inlet Reynolds. Comparison of numerical predictions with the experimental data showed that the AKN low Reynolds number turbulence model gave better agreement than the k–ε realizable turbulence model with the enhanced wall treatment.
-
Experimental Investigation of Convection Heat Transfer of CO2 at Super-Critical Pressures in Vertical Mini-Tubes and in Porous Media
Peixue Jiang,Yi-Jun Xu,Jing Lv,Run-Fu Shi,S. He,J. D. Jackson
DOI: https://doi.org/10.1016/j.applthermaleng.2003.12.024
IF: 6.4
2004-01-01
Applied Thermal Engineering
Abstract:Convection heat transfer of CO2 at super-critical pressures in vertical tubes with diameters of 0.948 and 4 mm and in porous media with particle diameters of 0.2–0.28 mm was investigated experimentally. The local heat transfer coefficients, fluid bulk temperatures, and wall temperatures were measured in the tests which investigated the effects of inlet temperature, mass flow rate, and heat flux on the convection heat transfer in the mini-tube and the porous tube. The variable thermophysical properties of super-critical CO2 and buoyancy significantly influenced the convection heat transfer in the vertical mini-tubes and in the porous media. The convection heat transfer in the porous tubes was very different from that in empty tubes.
-
Heat Transfer Characteristics of CO2 in a Horizontal Tube under Subcritical and Supercritical Pressures
Liang Cheng,Bingtao Hao,Jinliang Xu,Chengrui Zhang,Qingyang Wang
DOI: https://doi.org/10.1080/01457632.2023.2191440
IF: 2.3
2023-03-16
Heat Transfer Engineering
Abstract:Abstract Supercritical CO2 heat transfer in vertical tubes has been widely studied, but limited work exists for that in horizontal tubes. In this work, experiments were conducted for CO2 in a horizontal tube with inner diameter of 8 mm under wide range of pressures (5.51–20.41 MPa), covering both subcritical and supercritical conditions. The ranges of heat flux and mass flux were 97.5–404.0 kW/m2 and 510.2–1314.2 kg/m2s, respectively. The heat transfer for subcritical pressure far below critical pressure showed typical flow boiling characteristics, with a wall temperature peak along the tube corresponding to departure from nucleate boiling. For near-critical pressure, it showed characteristics similar to supercritical heat transfer, with continuous increase of wall temperature along the tube. The effects of different parameters including pressure, mass flux, and heat flux on the heat transfer behavior were analyzed and discussed. Moreover, using the pseudo-vapor quality concept of the supercritical three-regime-model introduced in a previous work, the heat transfer coefficient was found to behave very similarly between subcritical and supercritical conditions. The experimental results showed significant deviation from single-phase convection within the two-phase/two-phase-like region compared with the single-phase regions, and which validates the similarity between subcritical boiling and supercritical pseudo-boiling.
Environmental Science,Engineering
-
Experimental and Numerical Study of Convection Heat Transfer of Co2 at Supercritical Pressures in Vertical Porous Tubes
Pei-Xue Jiang,Run-Fu Shi,Chen-Ru Zhao,Yi-Jun Xu
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2008.05.014
IF: 5.2
2008-01-01
International Journal of Heat and Mass Transfer
Abstract:Convection heat transfer of CO2 at supercritical pressures in vertical sintered porous tubes with particle diameters of 0.1–0.12mm and 0.2–0.28mm was investigated experimentally and numerically. The study investigated the influence of the inlet fluid temperature, mass flow rate, pressure, particle diameter, heat flux, flow direction and buoyancy on convection heat transfer in porous tubes. The results show that the inlet temperature, pressure, mass flow rate, particle diameter and heat flux all strongly influence the convection heat transfer at supercritical pressures. When the inlet temperature is much larger than the pseudocritical temperature, Tpc, the local heat transfer coefficients in porous tubes are much less than when the inlet temperature is less than Tpc. For T0<Tpc and wall temperatures not much larger than Tpc, the local heat transfer coefficients have a maximum for both upward flow and downward flow along the porous tube when the fluid bulk temperatures are near Tpc. Buoyancy caused the different variations in the local heat transfer coefficients along the porous tube for upward and downward flows. The results also show that the heat transfer coefficients increase as the particle diameter decrease. The numerical simulations were performed using the local thermal equilibrium model with consideration of the effects of variable porosity, thermal dispersion and area-of-contact stagnant effective thermal conductivity. The experimental and numerical results for the friction factor of CO2 at supercritical pressures flowing in sintered porous tubes at constant temperature (without heating) corresponded very well with the known correlation. However, the predicted results for the friction factor of CO2 at supercritical pressures flowing in the heated sintered porous tube differ from those measured in the experiments both for upward and downward flows. The calculated wall temperatures corresponded well with the measured wall temperatures.
-
Special heat transfer characteristics of supercritical CO2 flowing in a vertically-upward tube with low mass flux
Qian Zhang,Huixiong Li,Xiangfei Kong,Jialun Liu,Xianliang Lei
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2018.01.112
IF: 5.2
2018-07-01
International Journal of Heat and Mass Transfer
Abstract:Due to limited studies on heat transfer of supercritical CO2 (S-CO2) at low mass flux, an experimental study was conducted on the High-TaP-SCO2 test loop to study heat transfer of S-CO2 in a 16-mm diameter tube with low mass flux. Fundamental data were collected at a pressure range of 7.5–10.5 MPa, mass flux of 50–500 kg/m2 s and heat flux of 5–100 kW/m2. The effects of heat flux, mass flux, and pressure on heat transfer at low mass flux were analyzed. Results showed that, with increasing heat flux, a completely different heat transfer phenomenon was observed at lower mass flux (G < 300 kg/m2 s) compared to a normal mass flux (G ≥ 300 kg/m2 s). Heat transfer at lower mass flux was not deteriorated but rather enhanced with a rising heat transfer coefficient, which is about 2.6 times higher than single-phase convective heat transfer. With mass flux decreasing from 400 to 100 kg/m2 s, heat transfer was enhanced about 5 times and turned from deterioration to enhancement. The mechanism of this heat transfer transition was further discussed. Results suggested that the special heat transfer enhancement at lower mass flux was mainly induced by the combined effects of strong buoyancy and high c p fluid. Based on the present dataset, existing Nusselt correlations for supercritical fluids were reevaluated, and these correlations failed in capturing the heat transfer enhancement occurring at low mass flux. Finally, a modified correlation for the heat transfer of S-CO2 at low mass flux was proposed within ±20% error and is available for the design of relevant devices with S-CO2.
engineering, mechanical,thermodynamics,mechanics
-
Experimental Investigation on Heat Transfer and Pressure Drop of Supercritical Carbon Dioxide in a Mini Vertical Upward Flow
Haicai Lyu,Han Wang,Qincheng Bi,Fenglei Niu
DOI: https://doi.org/10.3390/en15176135
IF: 3.2
2022-08-25
Energies
Abstract:Experiments on the convection heat transfer and pressure drop of supercritical carbon dioxide in a mini vertical upward flow were investigated in a smooth tube with an inner diameter of 2 mm. The experiments were conducted with pressures ranging from 7.62 to 8.44 MPa, mass fluxes ranging from 600 to 1600 kg·m−2·s−1, and heat flux ranging from 49.3 to 152.3 kW·m−2. Results show that the peak of heat transfer occurs when the bulk fluid temperature is below the proposed critical temperature and the wall temperature is above the proposed critical temperature. For the 2 mm vertical upward flow, the radial buoyancy effects are relatively weak, and the axial thermal acceleration effect cannot be negligible. In this study, a new modified Jackson correlation for the supercritical carbon dioxide is proposed for convective heat transfer. To reflect the effect of flow acceleration on heat transfer, a dimensionless heat flux was introduced to construct a new semi-correlation of heat transfer. The new correlation of friction factor taking into account the variation of density and dynamic viscosity was proposed with 146 experimental data within a ±20% error band.
energy & fuels
-
Investigation of Flow Boiling Heat Transfer Characteristics of CO2in Horizontal Mini-Tube
Zhang Liang,Jiang Linlin,Liu Jianhua,Zhao Yue
DOI: https://doi.org/10.1016/j.ijthermalsci.2018.11.032
IF: 4.779
2018-01-01
International Journal of Thermal Sciences
Abstract:In this paper, the characteristics of heat transfer for CO2 flow boiling in horizontal micro-tube were studied. Experimental conditions: saturated temperature: -40-0 degrees C, heat flux: 5-35 W m(-2), mass flow rate: 200-1500 kg m(-2) s(-1), inner diameter: 1.5 mm. Experimental results show that: the increase of heat flux has significant effect on enhancing nucleate boiling heat transfer, while it's can also speed up the dryout process and decrease the starting vapor quality of dryout; the effect of mass flow rate on heat transfer coefficient is slight but as mass flow rate increasing, the starting vapor quality of dryout decreases, and the heat transfer coefficient increases after the dryout happens; the effect of saturation temperature on the physical properties of CO2 is the main cause of the different heat transfer characteristics in different experimental conditions, with the increasing of saturation temperature, the starting vapor quality of dryout has a decline tendency and the heat transfer coefficient has a steeper fall after dryout happens. Compared with the prediction model, the Cheng's model has a higher prediction accuracy, it is presented with 77.1% of prediction accuracy ration within +/- 30% error band and 20.5% mean absolute deviation before dryout phenomenon, while it has only 22.9% and 57.8% after dryout phenomenon.
-
Influence Of Flow Acceleration On Convection Heat Transfer Of Co2 At Supercritical Pressures And Air In A Vertical Micro Tube
Pei-Xue Jiang,Rui-Na Xu,Zhi-Hui Li,Chen-Ru Zhao
DOI: https://doi.org/10.1115/IHTC14-22051
2010-01-01
Abstract:The convection, heat transfer of CO2 at supercritical pressures in a 0.0992 mm diameter vertical tube at relatively high Reynolds numbers (Re-in=6500), various heat fluxes and flow directions are investigated experimentally and numerically. The effects of buoyancy and flow acceleration resulting from the dramatic property variations are studied. The Results show that the local wall temperature varied non-linearly for both upward and downward flow when the heat flux was high. The difference in the local wall temperature between upward and downward flow is very small when the other test conditions are held the same, which indicates that for supercritical CO2 flowing in a micro tube as employed in this study, the buoyancy effect on the convection heat transfer is insignificant and the flow acceleration induced by the axial density variation with temperature is the main factor leading to the abnormal local wall temperature distribution at high heat fluxes. The predicted temperatures using the LB low Reynolds number turbulence model correspond well with the measured data. To further study the influence of flow acceleration on the convection heat transfer, air is also used as the working fluid to numerically investigate the fluid flow and heat transfer in the vertical micro tube. The results show that the effect of compressibility on the fluid flow and heat transfer of air in the vertical micro tube is significant but that the influence of thermal flow acceleration on convection heat transfer of air in a vertical micro tube is insignificant.
-
Numerical Investigation on Turbulent Heat Transfer of Supercritical CO2 in a Helically Coiled Tube
Xiao-Rui Huang,Zhen Zhang,Xing-Tuan Yang,Sheng-Yao Jiang,Ji-Yuan Tu
DOI: https://doi.org/10.1115/icone26-81748
2018-01-01
Abstract:Helically coiled tubes are widely used in many industrial applications such as the steam generator in the high-temperature gas-cooled reactor which is recognized as one of the new generation advanced reactors. The thermophysical properties of fluids exhibit drastic and fast changes in the pseudocritical region so that the flow and heat transfer characteristics of supercritical pressure fluids are greatly different from those at the subcritical pressure. The paper presents results of numerical investigation on turbulent heat transfer of supercritical CO2 in a helically coiled tube with a tube diameter of 9 mm, a coil diameter of 283 mm and a coil pitch of 32 mm under the constant wall heat flux. Both the RNG k-ε model with enhanced wall function and the SST k-ω model were applied in the simulations, and the results showed that the SST k-ω model agreed better with the experimental results in the literature. Effects of buoyancy and flow acceleration were evaluated. Details of developing heat transfer characteristics at three specific cross sections were analyzed. The heat transfer regularity and mechanism presented in this work can be useful for the design and development of more economic and safer design of the supercritical steam generator.
-
Impact of Conjugate Heat Transfer on the Turbulence and Heat Transfer in an Upward Heated Pipe Flow at Supercritical Pressure
Jundi He,Wei Wang,Bing Xu,Shuisheng He
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2024.126004
IF: 5.2
2024-01-01
International Journal of Heat and Mass Transfer
Abstract:Direct numerical simulations (DNS) of an upward heated pipe flow of supercritical CO2 (at Re0=3600) were carried out with and without conjugate heat transfer (CHT). The aim is to identify the impact of CHT on this specific flow problem and provide information for relevant numerical studies. The configuration is referred to one of the experiments carried out by Luo (2014), with a stainless steel (SS 304) pipe and a thermal activity ratio of 0.061. When CHT is introduced, the predictions of heat transfer coefficient (HTC) and wall temperature obtained in DNS are slightly improved against the experiment measurements. Two primary factors arise when CHT is considered, which are the axial redistribution of wall heat flux and the damping of the enthalpy fluctuations. The former affects the heat transfer particularly within a short distance after the inlet, leading to a more rapid establishment of the thermal boundary layer and a more rapidly progressing ‘laminarising’ process. The latter introduces substantial differences in the fluctuations of enthalpy (∼30 times difference) and density (∼40 times difference), which is however confined within a small region close to the wall and diminishes rapidly further away, resulting in a minor effect on turbulence and heat transfer in the main flow. When CHT is omitted, turbulent kinetic energy is over-predicted up to 1.55 times at most, in particular when the flow is being ‘laminarised’ (z/D<30). This is attributed to the discrepancies in shear production rather than the buoyancy production of the turbulent kinetic energy. Additionally, CHT alters both the laminar (Nul) and turbulent contributions (Nut) to the Nusselt number, with Nul starting at a lower level close to the inlet and the peak of Nut being reduced by 12.3%. These findings provide an insight on the impact of CHT on turbulence and heat transfer at different stages and valuable information for a more accurate modelling method for supercritical fluid flows.
-
Experimental study on forced convective heat transfer of supercritical carbon dioxide in a horizontal circular tube under high heat flux and low mass flux conditions
Junhui Wang,Pengcheng Guo,Jianguo Yan,Fengling Zhu,Xingqi Luo
DOI: https://doi.org/10.1177/1687814019830804
IF: 2.1
2019-03-01
Advances in Mechanical Engineering
Abstract:This study focuses on the convective heat transfer characteristics of supercritical carbon dioxide flowing in a horizontal circular tube under high heat flux and low mass flux conditions. The influences of thermophysical property, buoyancy effect, and thermal acceleration on the heat transfer characteristics are discussed. The parameters are as follows: system pressure is 7.6–8.4 MPa, mass flux is 400–500 kg/m 2 s, heat flux is 30–200 kW/m 2 , fluid temperature is 20°C −62°C, and Reynolds number is 1.23 × 10 4 to 4.3 × 10 4 . The wall temperature and heat transfer coefficient of supercritical carbon dioxide are obtained. The results show that, under the condition of high heat flux and low mass flux, heat transfer deterioration would happen, in which thermophysical property and buoyancy effect are the main factors. When the pressure is 7.6 MPa, the buoyancy factor is greater than 10 −3 in the whole heat transfer area, and the buoyancy effect cannot be ignored, while the thermal acceleration factor is 9.5 × 10 −8 to 4 × 10 −6 and the effect of thermal acceleration can be negligible. The experimental data are compared with the predictions using seven empirical correlations, in which the Liao–Zhao correlation shows the best performance.
engineering, mechanical,thermodynamics
-
Experimental Investigation of Conevection Heat Transfer of CO2 at Supercritical Pressures in a Vertical Circular Tube at High Re
LI Zhi-hui,JIANG Pei-xue
2008-01-01
Abstract:Convection heat transfer during the upward flow of CO2 at supercritical pressures in a vertical circular tube(din=2 mm) at high Reynolds numbers was investigated experimentally,and the effects of heat fluxes,mass fluxes,inlet temperatures,pressures,buoyancy and thermal acceleration on the convection heat transfer was analyzed.The results show that the tube wall temperature occurs abnormally distribution for high heat-fluxes with upward flow.The degree of deteriorated heat transfer increases with increasing heat flux.Increasing of the mass flux delays the occurrence of the deterioration of heat transfer and weakens the deterioration of heat transfer down-stream section.The inlet temperature strongly influences the heat transfer.The deterioration degree of heat transfer decreases with increasing pressure.
-
A Computational Study of Convection Heat Transfer to CO2 at Supercritical Pressures in a Vertical Mini Tube
S He,PX Jiang,YJ Xu,RF Shi,WS Kim,JD Jackson
DOI: https://doi.org/10.1016/j.ijthermalsci.2004.11.003
2004-01-01
Abstract:Computational simulations of experiments on turbulent convection heat transfer of carbon dioxide at supercritical pressures in a vertical tube of diameter 0.948 mm have been carried out using low-Reynolds number eddy viscosity turbulence models. The simulations were able to reproduce the general features exhibited in the experiments, although, in some cases, the details between the simulations and the experiments were very different. A better understanding of the problem has been developed based on the information generated by the simulations on the detailed flow and turbulence fields. It has been shown that for mini tubes such as the one used in the current study, the buoyancy effect is generally insignificant. However, heat transfer can still be significantly impaired as a result of flow acceleration when the heating is strong, which causes a reduction in turbulence production. Such an effect can be described in terms of the heating acceleration parameter Ω1. This parameter correlates reasonably well the data from all the cases considered in the current study.
-
Numerical Investigation of Heat Transfer Characteristics of scCO2 Flowing in a Vertically-Upward Tube with High Mass Flux
Kaigang Gong,Bingguo Zhu,Bin Peng,Jixiang He
DOI: https://doi.org/10.3390/e24010079
IF: 2.738
2022-01-01
Entropy
Abstract:In this work, the heat transfer characteristics of supercritical pressure CO2 in vertical heating tube with 10 mm inner diameter under high mass flux were investigated by using an SST k-ω turbulent model. The influences of inlet temperature, heat flux, mass flux, buoyancy and flow acceleration on the heat transfer of supercritical pressure CO2 were discussed. Our results show that the buoyancy and flow acceleration effect based on single phase fluid assumption fail to explain the current simulation results. Here, supercritical pseudo-boiling theory is introduced to deal with heat transfer of scCO2. scCO2 is treated to have a heterogeneous structure consisting of vapor-like fluid and liquid-like fluid. A physical model of scCO2 heat transfer in vertical heating tube was established containing a gas-like layer near the wall and a liquid-like fluid layer. Detailed distribution of thermophysical properties and turbulence in radial direction show that scCO2 heat transfer is greatly affected by the thickness of gas-like film, thermal properties of gas-like film and turbulent kinetic energy in the near-wall region. Buoyancy parameters Bu < 10−5, Bu* < 5.6 × 10−7 and flow acceleration parameter Kv < 3 × 10−6 in this paper, which indicate that buoyancy effect and flow acceleration effect has no influence on heat transfer of scCO2 under high mass fluxes. This work successfully explains the heat transfer mechanism of supercritical fluid under high mass flux.
physics, multidisciplinary
-
Characteristics of Heat Transfer for CO2 Flow Boiling at Low Temperature in Mini-Channel
Jiang Linlin,Liu Jianhua,Zhang Liang,Liu Qi,Xu Xiaojin
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2016.12.113
IF: 5.2
2017-01-01
International Journal of Heat and Mass Transfer
Abstract:This paper presents an experimental and theoretical investigation on two-phase flow boiling heat transfer with carbon dioxide (CO2 or R744) as the refrigerant in horizontal small diameter tube at low temperature. The experimental data were obtained in the following condition, the heat flux is 7.5-30 kW/m(2); the mass flow rate is 300-600 kg/m(2) s; the saturation temperature is 233-273 K; the test section is made of stainless steel tubes whose inner diameters are 0.6 and 1.5 mm. The experimental results show that heat transfer coefficient increases with the increase of mass flow rate, but decreases with the increase of tubes' inner diameter and saturation temperature, the boiling heat transfer of CO2 has a greater effect on nucleate boiling and highly depends on heat flux. The comparative study indicates that: during the existed flow boiling heat transfer model, the model which has the best prediction accuracy presented with 79.8% of predicted points within +/- 30% and 21.8% mean deviation before the dryout phenomenon happened, while it was only 18.4% and 59.9% after the dryout phenomenon happened. (C) 2017 Elsevier Ltd. All rights reserved.
-
Supercritical carbon dioxide heat transfer in horizontal tube based on the Froude number analysis
Liangyuan Cheng,Jinliang Xu,Wenxuan Cao,Kaiping Zhou,Guanglin Liu
DOI: https://doi.org/10.1016/j.energy.2024.130980
IF: 9
2024-03-16
Energy
Abstract:The heat transfer and pressure drop (Δ P ) of supercritical fluid are crucial for the safety of advanced power cycles. Here, experiments were performed for sCO 2 in a horizontal tube with inner diameter ( d in ) of 10 mm, covering in the ranges of ( G ): 496.7–1346.2 kg/m 2 , heat flux ( q w ): 97.4~400.3 kW/m 2 and pressure ( P ): 7.53–23.51 MPa. Inspired by the similarity of the outer wall temperature ( T ow ) distributions between the sCO 2 flow and those of stratified-wavy-flow in subcritical pressures, the multiphase flow theory is introduced in subcritical pressures to deal with the sCO 2 heat transfer. In the two-phase-like (TPL) regime, heat transfer coefficients (HTC) and friction factors ( f ) of sCO 2 are found to significantly deviate from the correlations based on the single-phase flow theory. Further, the vapor-like Froude number Fr VL is proposed to develop new correlations for both the heat transfer and the flow resistance covering the whole data range. The present paper establishes a connection between the flow resistance and heat transfer in supercritical pressures, which is important for the design and operation of sCO 2 power cycles.
energy & fuels,thermodynamics
-
Correlations of CO2 at Supercritical Pressures in a Vertical Circular Tube
LI Zhi-hui,JIANG Pei-xue
2010-01-01
Abstract:The experiment results of convection heat transfer of CO2 at supercritical pressures in a 2 mm diameter vertical circular tube for upward flow and downward flow were analyzed for pressures ranging from 78 to 95 bar,inlet temperatures from to 25 to 40℃,and inlet Re numbers from 3000 to 20000.The results were compared with some well known empirical correlations for the heat transfer without buoyancy effects and the heat transfer with strong buoyancy effects.It is found that there is a big deviation between the ex-periment results and empirical correlations.Based on the experiment data,correlations are developed for the local Nusselt correlations of CO2 at supercritical pressures in vertical circular tubes.
-
Numerical Study on Flow Structure and Heat Transfer of Supercritical CO2 in Tubes with Different Inclination Angles
Junren Hou,Yuan Zhou,Yuan,Shanfang Huang
DOI: https://doi.org/10.1016/j.pnucene.2023.105028
IF: 2.461
2024-01-01
Progress in Nuclear Energy
Abstract:To reveal how buoyancy affects heat transfer of supercritical carbon dioxide (sCO2), the flow and heat transfer characteristics of sCO2 in circular tubes with an inner diameter of 19 mm at different inclination angles were numerically investigated. The calculation results of RNG k−ϵ, RKE k−ϵ, SST k−ω and SST k−ω using a variable turbulent Prandtl number model (TWL model) have been compared with experimental data. The TWL model is chosen for numerical calculations because of its significant advantage in predicting wall temperature. Both forced convection (Richardson number Ri < 0.1, weak buoyancy) and mixed convection (Ri > 0.1, strong buoyancy) of sCO2 are calculated. Result shows that the position of the velocity peak moves upward, then downward as the flow changes from vertical upward (inclination angle α = 0°) to horizontal flow (α = 90°) due to the secondary flow caused by radial buoyancy and the increase in velocity magnitude in the near top wall region caused by axial buoyancy. Under strong buoyancy effects, as α increases from 0° to 90°, the heat transfer deterioration (HTD) becomes severe when α < 15°, then alleviated and finally severe again when α approaches 90° due to the change of the heat transfer mechanism. This work deepens our understanding of sCO2 heat transfer and may provide reference for the design of heat exchangers in nuclear reactors.
-
EXPERIMENTAL INVESTIGATION OF CONVECTION HEAT TRANSFER OF CO_2 AT SUPERCRITICAL PRESSURES IN VERTICAL CIRCULAR TUBE
LI Zhi-Hui,JIANG Pei-Xue,ZHAO Chen-Ru,LIN Yu-Song
2008-01-01
Journal of Engineering Thermophysics
Abstract:Convection heat transfer of CO2 at supercritical pressures in a vertical tube (Din=2 mm) was investigated experimentally in order to study the effects of the variation of physical properties, buoyancy and thermal acceleration on the convection heat transfer. For the case of low inlet Re number, the phenomenon of local wall temperature decrease was observed in upward flow which was not in downward flow. For the case of high inlet Re number, the local wall temperature showed an abnormal distribution due to the strong influence of buoyancy which result in the flow laminarization of the turbulence which was not observed in downward flow.