Standardization of the preparation and determination of novel biomarker-AOPPs

Yan-wen LU,Qiu-yu ZHU,Feng DING,Yong GU,Shan-tan LIN
DOI: https://doi.org/10.3969/j.issn.1672-8467.2008.01.005
2008-01-01
Abstract:Objective To standardize the preparation of hypochlorous-treated human serum albumin (HSA-AOPPs), cleanup of hypochlorous acid (HOCl) residue in HSA-AOPPs preparation as well as the determination of trace AOPPs. Methods Purified HSA (60 mg/mL) was oxidized with 60mmol/L HOCl (final concentration) under a stirring condition. The iodometry was used for the determination of HOCl residue in HSA-AOPPs preparation after purification steps by column chromatography or by dialysis. High performance size-exclusion chromatography (HP-SEC) was also used for quantitative analysis of trace AOPPs based on the area under curve (AUC) summarized from all the eluting protein area. Results Accuracy addition of HOCl was pivotal to a consistent concentration of HSA-AOPPs. It was best for the high yield of high molecular weight AOPPs when the molar ratio HSA/HOCl of 1 : 66. 5 was achieved and also for the elimination of the residues of HOCl in HSA-AOPPs by column chromatography in comparison with by dialysis. Overload of oxidant resulted in massive breakage of HMW-AOPPs with a cluster of protein fragments formation. There was a more than 100-fold increment in detecting the sensitivity by HPLC, compared to spectrophotometry. Conclusions Exact and consistent HSA/HOCl ratio is the key to standardize the HSA-AOPPs preparation. HP-SEC is a valid mean for the detection of trace AOPPs.