THE SPECTRAL CALIBRATION OF THE CLASS A SOLAR SIMULATOR

Xiaojing Peng,Lin Xu,Ze Guo
DOI: https://doi.org/10.3321/j.issn:0254-0096.2008.11.002
2008-01-01
Abstract:A design method of the filter film of solar simulator spectral calibration was presented: high voltage pulse Xe lamp was used to simulated solar spectrum as usual solar simulator, but the linear spectrum of the pulse Xe lamp were very strong. The film layers what needed were designed and analyzed on theory using the software of Macleod. The theoretical result through ideal film was offered. The film had been plated practically. The substrate of column pipe was instead of ling-eight pipe in order to reduce the cost. The practical measured result indicated the simulation was good and accord with the class A solar simulator standard.
What problem does this paper attempt to address?