Experimental Mensuration and Contrastive Study of fs and Qm of the Ultrasonic Vibration System

Ri-peng JIANG,Xiao-qian LI,Rong-guang LIU,Shi-cheng HU
DOI: https://doi.org/10.3969/j.issn.1004-2474.2008.06.040
2008-01-01
Abstract:The whole ultrasonic vibration system is taken as a researchful object,and the admittance circle,aided by computer,is measured according to the theory of force-electricity analogy.Based on the admittance circle,the syntony frequency fs and mechanical quality factor Qm of the vibration system in different load cases are acquired.Their variational rules are contrastively studied and the qualitative analysis of variational reasons for that is made.The study shows that fs and Q m generally decrease with the increase of working depth of the tool rod;the higher the load temperature is,the more obviously they decrease;with load viscosity increased,both fs and Qm decrease in different extents;and with its cross section area increased,fs has a little increase but Qm has been affected relatively lesser.On this basis,meanwhile,with the conditions of production and requirements of process considered,the optimum electrical matching of the ultrasonic vibration system and ultrasonic generator is confirmed,which has some referenced worthiness to aluminum alloy casting treated by ultrasonic.
What problem does this paper attempt to address?