Low Level Atmospheric Temperature Measurement with High Spectral Resolution Lidar

GUO Jin-jia,YAN Zhao-ai,WU Song-hua,SONG Xiao-quan,LIU Zhi-shen
DOI: https://doi.org/10.3321/j.issn:1005-0086.2008.01.017
2008-01-01
Abstract:A high spectral resolution lidar(HSRL) was used for low level atmospheric temperature measurement.Based on the iodine filters high absorption property for aerosol,the HSRL retrieves low level atmospheric temperature with Rayleigh backscattering signal intensity.The aerosol's influence in HSRL can be ignored.Using this method,we compared HSRL temperature measurement results with local radiosonde data.The results showed good agreement.The bias was less than 3 K below 9 km altitude.Furthermore,this paper discussed the system difference between the HSRL temperature measurement results and radiosonde data.The influence of initial temperature value selection at the reference altitude was also presented in this paper.
What problem does this paper attempt to address?