Feedback Analysis on Temperature Field of Ertan Arch Dam in Operation Period

王吉焕,金峰,王进廷,刘毅,王仁坤,杨剑
DOI: https://doi.org/10.3969/j.issn.1003-1243.2008.02.013
2008-01-01
Abstract:A lot of temperature data of Ertan arch dam have been recorded by the monitoring instruments installed within the dam body since its completion in 1998.Based on these measured data,feedback analysis of temperature field of Ertan arch dam is carried out by using the finite element method in this paper.Comparisons with the recorded temperatures show that the feedback temperatures agree well with the measured temperatures and display the actual temperature distribution in the dam body.The feedback analysis shows that the temperature field of the downstream face is nonsymmetric about the center line of arch dam in winter because the axis of dam approximates to the north-south direction.It should be noted that this temperature load is clearly different from the designed temperature load.
What problem does this paper attempt to address?