OPTIMIZATION OF SENSOR POSITIONS IN A TEST FOR IMMERSED TUNNEL HEALTH MONITORING

XU Feng,MENG Guang,PENG Hai-kuo,Ding Qi
DOI: https://doi.org/10.3969/j.issn.1000-3835.2008.02.020
2008-01-01
Abstract:Based on a health monitoring test for a similar immersed tunnel model of single section with seismic input,resorting to the tool of commercial FEA software ANSYS,the authors perform this model's plane strain analysis and overall modal analysis with equivalent seismic load and get the primary selection for sensor placement.Then,using the genetic algorithm,an optimal sensor placement is worked out.The result is almost the same as optimal sensor placement from the EFI method.The optimal approach proposed is helpful to optimal sensor placement of large structures.
What problem does this paper attempt to address?