Application of patch technique in artery reconstruction during adult liver transplantation

Bin Yi,Yong Yu,Xiang-ji Luo,Wei-feng Tan,Xiao-qing Jiang,Bai-he Zhang,Meng-chao Wu
DOI: https://doi.org/10.3321/j.issn:1673-8225.2008.31.002
2008-01-01
Abstract:Background: Vessel reconstruction and anastomosis are difficult in clinical liver transplantation. Patch technique in artery reconstruction of liver transplantation is important for expanding stoma diameter, reducing arterial thrombosis, promoting graft and recipient long-term survival. Objective: To investigate the application features and clinic values of patch techniques in artery reconstruction in recipients before total liver transplantation and in donors during transplantation. Design, time and setting: Single-center sampling and retrospective analysis. The experiment was performed at Eastern Hepatobiliary Surgery Hospital, Second Military Medical University of Chinese PLA from March 2004 to July 2006. Participants: Eighty patients underwent liver transplantation in Eastern Hepatobiliary Surgery Hospital, Second Military Medical University of Chinese PLA were selected. Donors were volunteers of brain death males. The donors and recipients were ABO matched. Methods: Artery reconstruction among donors was performed to retain and reconstruct total variant and injured arteries prior to implantation. Artery reconstruction among donors and recipients was performed during implantation. Thick and diameter-matched arteries were selected. Arterial anastomosis was conducted using patch technique. Donor or recipient arteries were trimmed to obtained arterial branches or root patches of anastomosis parts. Main outcome measures: The location of anastomosis, stoma diameter size and application of patch techniques were analyzed for four special sites respectively (proximal and distal part prior to and during implantation). Results: Twelve anastomoses in 11 cases were performed between donor arteries prior to implantation, 10 of which reconstructed due to aberrant right hepatic artery (AbRHA) arrived from superior mesenteric artery. On the donor arterial distal side in back-table reconstruction, the diameter of AbRHA with patch after anastomosis was larger than its end (t=5.423, P < 0.01). On the proximal side, spleen artery end was the location used more often (7/12) with a stoma diameter of (4.4±1.8) mm. In addition, 80 anastomoses were achieved during implantation. On the donor artery side during implantation, the common hepatic artery (CHA) branch patch, celiac artery end and proper hepatic artery (PHA) branch patch were often used, and possessed a location constituent ratio of 57.50%, 16.25% and 8.75% respectively. The diameter size did not differ statistically among them (P > 0.05). On the recipient artery side during implantation, the branch patch of CHA and PHA were usually anastomosed with a constituent ratio of 60.00% and 27.50%, but the diameter size of CHA was significantly larger than PHA (P < 0.01). The application rate of patch techniques differed statistically between anastomosis group prior to and during implantation (41.7%, 97.5%, P < 0.01). The patch application rates in four locations were 41.7%, 0.0%, 70.0% and 92.5% respectively. There was no statistical difference in application rate between donor distal side in back-table reconstruction and donor side during implantation (P > 0.05). The statistical differences were found between any other two groups (x2=13.292-51.004, P < 0.01). Conclusion: In back-table artery reconstruction prior to implantation, AbRHA adopting patch technique can get a larger stoma than its end. The application rate of patch techniques in artery reconstruction during liver implantation is higher than that in reconstruction prior to implantation, the recipient anastomosing side during implantation obtains the highest rate. With branch patch CHA can get a larger stoma than PHA with branch patch.
What problem does this paper attempt to address?