Performance of Thermochemical Sorption Deep-Freezing System Using Consolidated Composite Sorbent

LI Tingxian,WANG Ruzhu,CHEN Heng,WANG Liwei,WU Jingyi
DOI: https://doi.org/10.3321/j.issn:0438-1157.2008.z2.035
2008-01-01
Abstract:A thermochemical sorption deep-freezing system using manganese chloride-ammonia as sorption working pair was designed.For this test unit,expanded graphite was used as the porous medium of the reactant to improve the mass transfer inside the composite sorbent,and the consolidation technology was utilized to enhance the heat transfer performance.Experimental results showed that the additives of expanded graphite can avoid the agglomeration and the attenuation of sorption capacity.The consolidated composite sorbent could uptake 0,47 kg NH_3·(kg salt)~(-1).The chemical reaction between the composite sorbent and the refrigerant has a strong influence on the temperature evolution inside the reactor,and the sorption platforms were dissimilar at different evaporation temperatures.The lower the evaporation temperature,the lower the reactive rate.The specific cooling power(SCP)varied between 206 W·kg~(-1) and 706 W·kg~(-1) when the evaporation temperature ranged from—3 5℃to 0℃.For the thermochemical sorption deep-freezing system,SCP and coefficient of performance(COP)obtained with the consolidated composite sorbent were as high as 350 W·kg~(-1) and 0.34 respectively,at the cooling water temperature of 25℃and the evaporation temperature of -30℃.