Fire Safety of Long Tunnel Asphalt Concrete Pavement

HUANG Zhi-yi,WU Ke
DOI: https://doi.org/10.3785/j.issn.1008-973x.2007.08.040
2007-01-01
Abstract:Thermo-gravimetric analysis showed that the ignition points of SBS asphalt,flame-retardant asphalt and their corresponding mortars were 417~433 ℃,and their burning rates were 3.3×10-5~9.482×10-5 kg/(m2·s).Burning experiment of 1︰20 scale on the tunnel asphalt concrete pavement under 0~3 m/s air velocity showed that the depth of burned pavement under normal fire condition was lower than 4 cm.Simulations of long tunnel fire under different fire loads and air velocity were carried out by using non-premixed combustion model, κ-e turbulence model and P-1 radiation model.Results showed that no ignition of asphalt concrete pavement occurred when the fire load was lower than 10 MW;for 20 and 50 MW tunnel fire loads,the asphalt concrete pavement could not be ignited if the air velocity was higher than 2 and 4 m/s respectively;the influences of asphalt pavement combustion on tunnel fire were limited as the heat released from asphalt pavement combustion would not exceed 2.3% of the total fire load.Finally,the fireproofing structures of the tunnel asphalt concrete pavement and fireproofing strategies of tunnel fires were proposed.