Abstract:Research was on the continuous flow activated sludge system, using heavy metal-containing wastewater with the Cu2+ concentration of 1 mg/L, and 2, 6-dichlorophenol (DCP) as uncoupler with the concentration of 20 mg/L. Through 30 days continuous operation, we discovered that the removal efficiencies of COD was 4% lower than the control experiment, and sludge reduction would reach 70%, while 2, 6-dichlorophenol was not detected in the effluent, and the removal efficiency of Cu2+ was over 90%. But the sludge settleability and the removal efficiencies of nitrogen and phosphorus dropped, and sludge activity was higher than the control sludge. The microscope examination showed after 30 days' operation, filamentous bacteria in the sludge increased, while quantity and type of protozoon and metazoa reduced. The result indicated that Cu2+ and 2, 6-dichlorophenol had the obvious cooperation to the sludge reduction, so using heavy metal and uncoupler to limit the sludge yield in the continuous flow activated sludge system was feasible.