Numerical Simulation of a 270°bending Magnet System with an Adjustable Target Position

LI Quanfeng,WANG Guangqiang,XING Qingzi,CHEN Huaibi
DOI: https://doi.org/10.3321/j.issn:1000-0054.2007.12.020
2007-01-01
Abstract:A 270° bending magnet system for moderate/high energy medical accelerators was designed for precise positioning during radiotherapy.The magnetic field distribution in the system was calculated using MAFIA code,a 3-D electromagnetic CAD system.The beam was traced by solving the motion equations of the electrons in the electromagnetic field using the Runge-Kutta method.The results show that the electron beam position arriving at the target could deviate from the target center due to manufacturing and installation uncertainties.Therefore,a small coil was added to the middle magnet to fine-tune the magnetic field.Proper control of the current in the coil could then automatically provide precise positioning of the beam on the target.
What problem does this paper attempt to address?