Method for Determining Deep Ground Thermal Properties Accounting for Water Advection

YU Mingzhi,PENG Xiaofeng,FANG Zhaohong,LI Xiaodong
DOI: https://doi.org/10.3969/j.issn.1005-0930.2007.02.008
2007-01-01
Abstract:A heat transfer model accounting for groundwater advection was proposed for determining the thermal conductivity and volumetric specific heat capacity of deep ground soil conveniently at worksites.The heat transfer between the buried geothermal heat exchanger and surrounding ground was considered as a moving line-source in an infinite medium.This model did not need exact information of the buried U-tube location,spacing between up and down tubes,the properties of the tubes and backfills,and other parameters in borehole as usual cases.A practical site test was conducted to obtain heat flux imposed on the buried loop,water flow rate,temperatures at the outlet and inlet of the loop by an in-situ measuring apparatus.The model,together with optimal estimation algorithm,was used to determine the thermal properties of the deep ground soil and groundwater advection velocity at the worksite.
What problem does this paper attempt to address?