Biomechanical alterations during the treatment of thoracolumbar vertebral compression fractures with repositor

Y Dong,SP Sui,GY Wang,Y Chen,K Bao,CY Jiang,BF Zeng
DOI: https://doi.org/10.3321/j.issn:1673-8225.2007.51.010
2007-01-01
Abstract:AIM: The reposition of thoracolumbar vertebral compression fracture is always achieved by Harrington rob or Dick compression to reset the compressed vertebral body indirectly. However, the strength of reposition is very difficult to control, consequently, the curative effect is always dissatisfactory. Therefore, it is necessary to explore the maximal stress that the repositor can bear before its distortion occurs and investigate the correlation between the force and displacement caused by the repositor when it opens in fractured vertebrae. METHODS: The experiment was carried out in Shanghai Institute of Material Mechanics, Institute of Biomechanics of Shanghai Ninth People's Hospital and Department of Anatomy, Shanghai Second Medical University from October 1998 to April 2003. The self-designed vertebral repository was cylindrical and the up and down unlock was controlled by the caudal end round handle. ①The repositor was distracted completely and put on the platform of a dynamometer. The axial stress that the repositor was distorted served as the maximal stress it could bear. ②The compression fracture models were established in 36 fresh calf vertebra and the correlation between the axial load and distortion was explored. The vertebral height was measured before experiment and after distortion. Meanwhile, the corresponding stress values were recorded. ③Twenty fresh calf thoracolumbar vertebra were divided into 2 groups (n =10). The models of compression fracture were constructed by increasing the axial loads on the vertebrae. In 1/2 compression group, the vertebrae were compressed to 1/2 of their original heights and 2/3 in 2/3 compression group. The repositor was inserted from two sides of neck of vertebra to reset the compressed vertebra. The correlation between the force and displacement caused by the repositor when it opens in fractured vertebrae was observed. RESULTS: ①The maximal stress which the repositor could bear before its distortion occurred was 281 N. ②The minimal axial loads causing the distortion of fresh calf vertebrae averaged out to 74.96 kPa. And the result represented a normal distribution (t =16.044, P < 0.01). ③The average minimal force used to restore compressed vertebra in 1/2 and 2/3 compression groups showed no statistical difference (t =0.835, P > 0.05). CONCLUSION: There is no direct correlation between the severity of compressive fracture and the force to restore the compressed vertebra. The force of self-designed repositor to restore the compressed vertebra is much smaller than the stress to cause the distortion of repositor.
What problem does this paper attempt to address?