Fire-resistant experimental study on fire and corrosion resistant steel-concrete composite beams

WANG Wenhao,YU Xianglin,CHENG Yun,SHI Yongjiu,PANG Yiukwong,LIU Guanghui
DOI: https://doi.org/10.19701/j.jzjg.20210685
2023-01-01
Abstract:Fire-resistant tests of two types of steel-concrete composite beams are presented. One is 'main beam type' test, in which the steel beam is parallel to the rib of metal deck, and the other is 'secondary beam type' test in which the steel beam is perpendicular to the rib of metal deck. During the test, the furnace temperature, temperature of different sections of the specimens and mid-span deflection are measured. The conclusions are as follows: 1) the temperature of the concrete slab rises much slower than that of the steel beam, and has a great influence on temperature distribution of cross section of the steel beam due to the low thermal conductivity of the concrete slab; 2) due to the high temperature and imposed load, shear failure of the concrete occurs possibly at the end of the beam. However, shear studs remain intact thanks to the protection from the concrete slab; 3) once the mid-span deflection reaches 1/30 of the beam span, the deflection will rapidly and continuously increase until a distinguished crush crack occurs in the concrete slab, named as 'plastic hinge' formed in the mid span of the specimens.
What problem does this paper attempt to address?