Design and optimization of improved planar bending ESMAAs

Kai Yang,ChengLin Gu,YAN Xin-rong
DOI: https://doi.org/10.3321/j.issn:0258-8013.2007.06.010
2007-01-01
Abstract:To overcome low response speed and low control precision in the existing planar bending ESMAAs, the structures of actuators were improved. Two SMA wires were embedded in parallel with the axis of the elastic rod. The recovering wire, which was superposed along rod's axis, was set to obtain 'U' memory shape and the restoring wire, which was placed off-axially, got straight memory shape. The differential stain gauges were located at suitable position in corresponding to the actuator's bending direction in order to measure the signal of displacement. By making use of continuity, common origin and common limit conditions and adjusting martensite fraction coefficients appropriately, the analytical model was deduced to adequately account for the presence of major and minor hysteresis loops. The structural parameters of 60 mm long actuator, such as rod's radius, wire's radius, wire's recoverable curvature and offset distance, were optimized by combining analytical model with experimental results. The experimental results prove the merits in optimal prototype.
What problem does this paper attempt to address?