A Study of the Effect of Blade Rotating Angles on the Performance of a Louver Concentrator
孙绍增,王志强,姜文龙,张晓辉
DOI: https://doi.org/10.3969/j.issn.1001-2060.2007.04.016
2007-01-01
Abstract:By making use of a louver concentrator test system,a study was conducted of the effect of rotating angles of blades in five stages on the performance parameters of the concentrator (dense-thin air ratio R1,resistance loss coefficient D and average concentration rate R2).Through an analysis of test results of blades in various stages rotating at different angles,obtained was a change of the performance parameters caused by the variation of blade rotating angles.Regarding the rotating angles of blades in various stages,the operating condition corresponding to a maximal resistance coefficient was found to be one when all the blades in the fifth stage are rotating at 30 degrees.The operating condition featuring a maximal dense-thin air ratio was one in which the blades in the first to fourth stage are rotating at 30 degrees while the blades in the fifth stage at 20 degrees.The operating condition corresponding to a maximal concentration rate was one when all the blades in the fifth stage are rotating at 30 degrees.
What problem does this paper attempt to address?