Application Of Principal Component Analysis In Calibration Sample Selection Of Near-Infrared Quantitative Model

Li Yan-Zhou,Min Shun-Geng,Xia Liu
DOI: https://doi.org/10.3321/j.issn:0253-3820.2007.09.019
IF: 1.193
2007-01-01
Chinese Journal of Analytical Chemistry
Abstract:Principal component analysis technique was applied to calibrating sample selection of near-infrared quantitative model. A simple and reliable method in selection of samples for calibration was proposed, which choose calibration samples according to scores of the first principal component of near-infrared spectrum. Calibration sets contained about 105 samples were selected front 418 tobacco samples using the method proposed and the other two methods named Random method and Content Grads method. Quantitative models of nicotine were established and tested respectively to compare the performances of these three selection methods. Results show that the method bring forward has good ability to choose calibration samples using spectrum data only. It can avoid the risk of lacking representativeness caused- by Random method as well as the large workload to determine concentrations of all the samples using Content Grads method. In addition, the method is simple and easy to be used.
What problem does this paper attempt to address?