Performances Analysis of the Organic Rankine Cycle Driven by Exhaust under Disturbance Conditions

WEI Dong-hong,LU Zhen,LU Xue-sheng,GU Jian-ming
DOI: https://doi.org/10.3321/j.issn:1006-2467.2006.08.031
2006-01-01
Abstract:The performance predictions of organic Rankine cycle(ORC) using R245fa(1,1,1,3,3-pentafluoropropane) as organic working fluid driven by exhaust were presented.Based on the developed and validated modeling program, the thermodynamic performances of an ORC system under disturbance conditions were analyzed.The results show: using exhaust as much as possible is a good way for the improvement of system performance;the degree of sub-cooling at the outlet of condenser should be in an appropriate range,(0.5)~(0.6) K is appropriate to this cycle;when the temperature of environment is too high,the system export performance would be deteriorate,in the summer the deviation to nominal state would be excess 30%;and according to the real situation choosing a proper nominal state is a good idea to the efficient working of the system.
What problem does this paper attempt to address?