An Adjusting Equipment of Crystal Chamber with 3-3PS Parallel Manipulator in a Double-Crystal Monochromator

CAO Chong-zhen,YU Hui-tao,MA Pei-sun,GAO Xue-guan,WANG feng-qin
DOI: https://doi.org/10.3321/j.issn:1006-2467.2006.02.009
2006-01-01
Abstract:In order to overcome the shortcomings of the adjusting equipment for crystal chamber in a double-crystal monochromator,a novel adjusting equipment was put forward,which utilizes 3-3PS parallel manipulator to adjust the 6-DOF pose of crystal chamber.The mechanism model,freedom calculation,inverse kinematics of 3-3PS parallel manipulator were analyzed.The structure of the adjusting equipment with 3-3PS parallel manipulator was introduced.The novel equipment was applied in the double-crystal monochromator of XAFS beam line in Beijing Synchrotron Radiation Facility.Its position adjustment precision is excelled to 0.05 mm,and its attitude adjustment precision is excelled to 10 arcsec.
What problem does this paper attempt to address?