Removal of Chlorobenzene and Toluene by Dielectric Barrier Discharge (DBD) of Ambipolar Pulse High Voltage

LI Duan,LIU Ming-hui,WU Yan,LI Guo-feng,LI Jie
DOI: https://doi.org/10.3321/j.issn:1000-6923.2006.z1.007
2006-01-01
Abstract:Ambipolar pulse high voltage was introduced into dielectric barrier reactor (quartz glass medium and stainless-steel electrode with screw) to test study the decomposition character of Chlorobenzene and toluene. This electric discharge way could inject effectively energy, and had both the characters of pulse corona and dielectric barrier discharge. Pulse high voltage enhanced rapidly the intensity of electric field, and produced instantaneously strong discharge and highly energized particles and could realize highly effective fission of chemical bonds of VOCs. Comparing the test results of working frequency interflow high voltage and monopolar pulse high voltage, showed that highest removal efficiency was gained with ambipolar pulse voltage; chlorobenzene was removed more difficultly than toluene.