An Energy-saving Process Integrated by Ethylene Quenching Section and Delayed Coking Unit

Xin-bo CAO,Zhi-gang TANG,Zhan-ting DUAN,Nai-ju YUAN
DOI: https://doi.org/10.3321/j.issn:1009-606X.2006.02.022
2006-01-01
Abstract:A new method involved in waste heat recovery of high temperature gas, using waste heat as the heat source of an endothermic reaction so as to transfer physical exergy of the waste heat into chemical exergy of the reaction products, was presented in this paper. As an example, a novel process, the energy-saving process integrated by ethylene quenching section and delayed coking unit, was introduced to recover waste heat of the ethylene pyrolysis gas by delayed coking reaction. The results indicated that a pyrolyzer with annual ethylene capacity of 60 kt can match a delayed coking unit with annual process capacity of 880 kt. And the exergy recovery rate of the quenching process can be increased from 64.0% to 74.4%. Besides, this integrated process will have the advantages of lower equipment investment, longer steady running period, etc.
What problem does this paper attempt to address?