Effect of different electrical parameters on transdermal delivery of sinomenine using eletroporation

Qi-feng YUE,Bao-hua HAO,Zhou-hu DENG,Wei-ze LI,Yao-wu GUO,Han ZHANG,Yi-chao WANG,Sen LIU
DOI: https://doi.org/10.3321/j.issn:0253-2670.2006.11.016
2006-01-01
Abstract:Objective: To observe the effects of different electrical parameters (voltage, shap of wave, pulse width, and number of pulses) on transdermal delivery of sinomenine using eletroporation. Methods: The transdermal penetration in Franz diffusion cell for isolated rat skin of sinomenine was studied by different electrical parameters of electroporation equipment for Chinese materia medica, respectively. The content of sinomenine per-meated abdomen skin of mice was determined by HPLC. Results: The accumulative permeation of sinomenine was correlated with electrical parameters, different electrical parameters showed the significant effect on sinomenine's transdermal delivery. The optimum electrical parameters were voltage: 600 V, shap of wave: the combination of square wave and sine wave, pulse width: 500 μs, number of pulses: 240. The permeation increased significantly and the increasing extent was 5 - 100 times compared with the passive diffusion. Conclusion: Optimum parameters of eletroporation have an favorable future for active constituents in Chinese materia medica to be transdermically deliveried.
What problem does this paper attempt to address?