Design and biomechanical study of the grooved interlocking dynamic compressing medullary nail

Hong-wei Yan,Kun-zheng Wang,Kai Liu,Jun Liu,Jin-hui Song,Hong-gahg Wang,Kai-fang Zhang,Guo-lian Yuan
DOI: https://doi.org/10.3321/j.issn:1673-8225.2006.29.046
2006-01-01
Abstract:AIM A new type of the grooved interlocking dynamic compressing medullary nail for femur and tibia is manufactured and tested for its biomechanical performance and to access its feasibility to be applied for fracture internal fixation. METHODS The experiment was carried out at material biomechanical laboratory of Xi'an Jiaotong University from March to June 2005. Ten pairs of the new Ti-6Al-7Nb femoral and tibial interlocking medullary nails were taken as experiment group 10 pairs of imported Orthofix interlocking medullary nails of the same specifications were taken as control group. They were tested on the MTS880 machine with the rate of 1mm $10 min to get the results of the axile-pressure tests Fmax=2 400 N the maximal three-point bending moment 64 N·m and the dynamic fatigue Fmax=1 200 N Fmin=600 N with the rate of 1 mm$min when frequency was 15 Hz femal and 13 Hz tibia. RESULTS ① The result of the erect compression test showed that the strain and the displacement of the distant locking hole increased along with the increase of loading. When loaded with 2 400 N the strain of experiment femoral nail and control nail was(5.502±0.09) με and(1.74±0.13) με respectively the displacement of the distant locking hole of experiment femoral nail and control nail was(326.42±2.242) μm and (139.320±1.74) μm respectively the strain of experimental tibial nail and control nail was(10.89±0.14) με and (5.37 ±0.04) με respectively the displacement of distant locking hole of experiment tibial nail and contrapose nail was (94.90±2.66) μm and(72.69±2.84)μm respectively. There was obvious difference between experimental nail and control nail according to the strain and the distortion when loaded with erect compression P < 0.05. ② When the flexing-moment was 64 N·M the flexibility of experiment femoral nail and contral nail was (2 616.64±4.82) μm and(1 184.93 ±5.51) μm respectively  the flexibility of experiment tibial nail and control nail was (3 648.22±3.37) μm and(1 994.95±3.81) μm respectively. The experiment nails got better performance than the control ones because of its superior elasticity. ③ The new femoral and tibial nails endured 600 000 and 680 000 circulations respectively with axial pressure range from 600 N to 1 200 N the anti-compression capability remained constant when circulations of axial pressure were given P > 0.05. CONCLUSION The new-manufactured femoral and tibial nails perform excellent static and dynamic intensity and can satisfy the clinical requests.
What problem does this paper attempt to address?