Stimulator for experimental use in epidural spinal cord stimulation

Yong-ji Wang,Xiao Zhang,Ji-ping He,Qi Xu
DOI: https://doi.org/10.3321/j.issn:1673-8225.2006.29.051
2006-01-01
Abstract:AIM Clinical research has indicated that applying epidural spinal cord stimulation on patients with incomplete spinal-cord injury can improve their walk speed and endurance modulate energy metabolism during walking by increasing fat metabolism and reducing carbohydrate metabolism. To discover the underlying mechanism we designed an animal experiment system using in epidural spinal cord stimulation. METHODS ①Principle of Epidural Spinal Cord Stimulator and circuit design The hardware consisted of MCU man-machine interface circuit D$A circuit and waveform circuit. The MCU was made use of AT89S51 produced by ATMEL of U.S. with 4 KB programmable Flash read only memory and high-performance CMOS 8 bits single chip. The man-machine interface circuit was mainly used to provide real time parameter and input to users. ②Range of simulator parameters 0-10 V voltage amplitude each gear was 0.1 V could be modulated up or down 500-1000 Hz frequency each gear was 100 Hz could be modulated up or down and 0-100 μs pulse width each gear was 5 μs could be modulated up or down. ③Waveform of the stimulation Charge balance dual pulse was selected. ④Electrode and the material of its lead Silver was used as the material of electrodes and leads in order to make the stimulate point accurate and silica gel encapsulate was used as the electrodes to ensure compatibility. Electrodes and leads were encapsulated in the silica gel module and the electrode chips were exposed to touch and stimulate the spinal cord. The electrode chip was 1.7 mm in diameter and the lead was 0.2 mm the space between electrode chips was 3 mm. ⑤Animal experiment It was collaborated with Department of Neurological Rehabilitation of Tongji Hospital. The L4 and L5 bulgy parts on the lumbar of 5 adult healthy cats were selected and their skin was sliced off to separate backbone and surrounding tissue and cut off spinal process and vertebral plate under the circumstances of local anesthesia then the epidural spinal cord fat and epidural spinal of the cats were unfolded. The electrode was planted into epidural spinal cord and the lead of the electrode was connected to stimulator. The stimulation was given with low voltage and frequency which was boosted step by step. The anode and cathode of the three electrodes were exchanged and then the stimulation above was repeated. Whether the muscle in the stimulated section jerked or not was used to judge the stimulated effect. RESULTS ①The AT89S51 MCU served as the core had a wide modulated range. ②The feasible charge balance dual pulse obtained from the animal reaction was safety and reliable. ③In the early stage of the experiment the 5 cats jerked slightly when the stimulate voltage reached about 1±0.1 V 700±100 μs 40±5 Hz. The bigger the value the larger the degree of the muscle jerks. Increasing the stimulate intensity in different extent by means of changing frequency and waveform width could also change the degree of the muscle jerk. No bad effects were found in the cats during experiment. CONCLUSION This simulator can meet all the needs in the research of epidural spinal cord stimulation and provide flexible and safe simulated voltage according to the needed parameters in the experiment and its man-machine interface can make operation convenient. This simulator is a good device used in further research of epidural spinal cord stimulation.
What problem does this paper attempt to address?