Experimental Study of the Load Capacity of a Gabled Arch Frame Steel Building

WANG Yuanqing,SHI Fei,ZHANG Yong,SHI Yongjiu
DOI: https://doi.org/10.3321/j.issn:1000-0054.2006.06.002
2006-01-01
Abstract:The load capacity and deformation of a 10-m spanned gabled arch steel frame were measured with static loading conditions.The test model and another model with the same span,span-height ratio,and sectional dimensions were analyzed using the finite element analysis software ANSYS.The results show that the gabled arch steel frame has better integral stiffness for the same loads and geometric conditions than standard arches.Gabled arch steel frames make better use of the material strength to increase the loading capacities and reduce the deformations.