Three-Level Dc-Dc Converter: Four Switches V-Smax=V-In/2, Tl Voltage Waveform Before Lc Filter

Yong Shi,Zhijian Jin,Xu Cai
DOI: https://doi.org/10.1109/PESC.2006.1711781
2006-01-01
Abstract:Novel TL DC-DC Converter is proposed, which utilized four series connected switching device and two blocking capacitors to provided middle electrical levels. The voltage stress on each switch is V-in/2. Three levels can be applied before output inductor, and as a result the value of output inductance can be reduced to 1/2 compared with traditional Full Bridge DC-DC converter. With output frequency double control the value of output inductance can be reduced 50% further as conventional TL converter. The principle of operation and the do characteristics of the new converter are analyzed and verified on a 100W experimental prototype.
What problem does this paper attempt to address?