The Research of Harmonic Circulating Current Restrain in Parallel Inverter Systems

ZHANG Yu,DUAN Shan-xu,KANG Yong,CHEN Jian
DOI: https://doi.org/10.3321/j.issn:0258-8013.2006.12.012
2006-01-01
Abstract:In inverters,the distortion of the output sine voltage caused by factors like dead-times of power switches can be well compensated by the instantaneous voltage feedback regulators like PID controllers.However,in our experiments,we found that the dead-times could result in significant large circulating currents,and the instantaneous regulators had limited effect on restraining them,esp.in large power parallel systems where the filter reactors and output impedences must be small.In this paper,for analysis of the harmonic circulating currents,an inverter model that considered the bias of SPWM as a disturbence was established.The research of the restrain on harmonic circulating currents by the instantaneous regulators indicated that there had been relation between the output voltage distortion restrain and the harmonic circulating currents restrain by the regulators.The compare of the single loop and duel loop control demonstrated that regulators that can achieve good waveforms could also lead to the better restraining of the harmonic circulating currents.The experiments and simulation validated the conclusion.
What problem does this paper attempt to address?