An experimental study of full-scale semi-rigid composite frames under vertical loading

Guoqiang Li,Jingfeng Wang,Qingping Liu
DOI: https://doi.org/10.3321/j.issn:1000-131X.2006.07.008
2006-01-01
Abstract:Results are presented for a pair of tests of full-scale two-storey-two-bay semi-rigid composite frames. The composite frame is composed of H-shape steel columns and composite beams with steel plates. The steelwork connection consists of a flush end plate welded to the end of the beam and bolted to the column flange. To investigate the influences of semi-rigid joints and slabs on the performance of steel frames, overall response of the frame, connection behavior and beam behavior are analyzed. It is found that the composite endplate connection, which acts as a semirigid and partial-strength node, has high strength and rigidity; it satisfies the ductility design requirement that rotation capacity can be no less than 30 mrad. Therefore, the effects of semi-rigid joints and slabs on the strength, rigidity and ductility of steel frames should be properly taken into consideration in design.
What problem does this paper attempt to address?