SIMULATIVE EXPERIMENTAL STUDIES ON A MULTI-EFFECTS REGENERATION SOLAR DESALINATION UNIT WITH HORIZONTAL TUBE FALLING FILM EVAPORATION AND INNER SYSTEM SELF-EQUILIBRIUM

Hongfei Zheng,Yingjun Yang,Ziqian Chen,Kaiyan He,Hui Li
DOI: https://doi.org/10.3321/j.issn:0254-0096.2006.05.013
2006-01-01
Abstract:Based on the analysis on mechanism of the falling film evaportation and the falling film condensation, a new solar desalination unit with three effects regeneration was designed. Simulative experimental study on the performance of the unit using solar collector with electric booster was carried out. The results indicated that the unit has higher performance ratio because of the most latent heat of vapoor and the heat of the water being utilized several times again based on the utilization of the horizontal falling film evaporation and condensation processes. When the operation temperature is over 75°C and the inner pressure is lower 15 kPa, the performance ratio of the unit can reach 2.0. The main factors influencing the performance of the unit were studied and analyzed. The suitable range of the parameters was provided.