Investigation On The Crystalline Transition Of Nylon-6 18

D Xiao,Xw Cui,Wh Li,Dy Yan
2006-01-01
Abstract:The Brill transition of even-even nylon-6 18 was investigated by using differential scanning calorimetry (DSC ), temperature-dependent wide angle X-ray diffraction (WAXD) and Fourier transform infrared (FTIR). The X-ray diffraction results indicate that the melt-crystallized sample of nylon-6 18 transforms from the triclinic unit cell to the pseudo-hexagonal phase in the temperature range of 120-180 degrees C. In this range, the thermograph of nylon-6 18 presents a broad endothermal peak. From the FTIR spectra, it can be found that, during the transition process of nylon-6 18, the intensity of the intrasheet hydrogen bonds becomes weak. At the same time, the CH2-amide bonds twist and the all-trans conformation of methylene sequences is disordered by inserting the gauche conformation. The CH, segments are in a mobile state because of the enhanced stretching and twisting vibrations of C-CO and C-N bonds.