Abstract:OBJECTIVE: To establish HPLC assay for the determination of oridonin concentration in mice liver. METHODS: The liver samples were extracted with ethyl acetate and the solvent was evaporated to dryness by N2. The residue was dissolved by methanol. The separation was performed on a Phenomenex-ODS column (150 mm × 4.60 mm, 5 μm) with the mobile phase consisted of methanol water (60: 40) at a flow rate of 1.0 mL·'min -1. UV detection wavelength was at 239 nm. RESULTS: The calibration curve was linear over the range of 0.5 - 90 μg·g-1 (r = 0.997 7)and the limit of detection was 20 ng. The extraction recoveries were 73.76% - 79.08% (n = 5). The recoveries of the assay were 85.14% - 90.58% (n = 5). The RSDs of intra-day and inter-day didn't exceed 7.30% and 13.63% (n = 5), respectively. CONCLUSION: The present study provided a sensitive, accurate and reliable method for the determination of oridonin in mice liver and the evaluation of hepatic targeting efficiency.
What problem does this paper attempt to address?