Determining Spontaneous Combustion Danger Zones and Predicting Spontaneous Combustion During Mining Near-Neighbored Coal Seams

ZHANG Xin-hai,XI Guang,CHEN Xiao-kun,DENG Jun,WEN Hu
DOI: https://doi.org/10.3321/j.issn:0253-9993.2005.06.012
2005-01-01
Abstract:A numeric algorithm was taken to solve coupled steady model of air flow,diffusion and chemical reaction in multi-layer neighbored coal seams and rocks,and oxygen concentration and flow velocity magnitude in different position was obtained.Oxygen concentration and flow velocity together with loose coal thickness were compared with their critic value obtained from large-scale coal spontaneous combustion experiment to determine spontaneous combustion danger zone.Connecting the result with velocity of the mining workface and the experimental spontaneous combustion duration,date of spontaneous combustion can be predicted.The method was employed to predict spontaneous combustion in coal pillar during mining the adjacent substrate coal in Dongrong No.2 coalmine successfully.The result showed that self-heating zone lies in 50~140 m in the airflow inlet side and in 50~85 m in outlet side away from the workface in the coal pillar.If moving velocity of the workface is larger than 1.6 m/d,there is no danger of spontaneous combustion;while if the workface stopped to move but ventilation kept normal for 38 d,spontaneous combustion will take place in airflow inlet side of the pillar.
What problem does this paper attempt to address?