Measurement of radiation temperature in hohlraum with shock wave method on Shenguang II laser facility

Shaoen Jiang,Wenhong Li,Kexi Sun,XiaoHua Jiang,Yonggang Liu,Yanli Cui,Jiusen Chen,Yongkun Ding,Zhijian Zheng
2005-01-01
Abstract:The D shaped cavity has been used to measure the radiation temperature in Hohlraum on Shenguang II laser facility. The radiation temperature was measured using two methods. One method measured the shock wave velocity produced in low-Z materials such as Al driven by the emission from hohlraum. The shock velocity was detected using optical streaked camera to observe the optical signal emitted from the rear of a step Al placed over a hole in the cavity wall. The second method measured the re-radiated X-ray flux from the cavity wave viewing through another hole in the cavity with soft X-ray spectrometer. Both methods have been shown to provide a consistent characterization of the X-ray drive in the cavity target. The experimental results were analyzed using a model that was based on heat wave similarity and energy conversation law.